CANAL WINCHESTER, OH ·
OSHA Inspection: RAFAEL MORA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RAFAEL MORA in 5434 BOWYER COURT, CANAL WINCHESTER, OH 43110 (NAICS 238170). OSHA activity number 343849329.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAFAEL MORA
- Site address
- 5434 BOWYER COURT
- City
- CANAL WINCHESTER
- State
- OH
- ZIP
- 43110
- Mailing
- 3989 BRIGGS ROAD, COLUMBUS, OH 43228
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 4
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1926.20 B01
- Issued
- Mar 28, 2019
- Abate by
- Apr 17, 2019
- Penalty
- Initial $3,978 · Current $1,989 Reduced
General-duty citation text
29 CFR 1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part. a. Located at 5434 Bowyer Court in Canal Winchester, Ohio: On or about March 13, 2019, the employer did not maintain an effective safety and health program onsite to ensure fall hazards and unsafe use of scaffolds were identified and corrected onsite.
Recent events (2)
- · I (S) $1989
- · Z (S) $3978
1926.451 G01
- Issued
- Mar 28, 2019
- Abate by
- Apr 17, 2019
- Penalty
- Initial $3,978 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. a. Located at 5434 Bowyer Court in Canal Winchester, Ohio: On or about March 13, 2019, the employer did not ensure that the employee performing siding work on the front of the house from a pump jack scaffold was protected from falling approximately twenty foot. The personal fall arrest system used was not properly anchored.
Recent events (2)
- · I (S) $0
- · Z (S) $3978
1926.451 G03 I
- Issued
- Mar 28, 2019
- Abate by
- Apr 17, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(3)(i): When vertical lifelines are used, they shall be fastened to a fixed safe point of anchorage, shall be independent of the scaffold, and shall be protected from sharp edges and abrasion. Safe points of anchorage include structural members of buildings, but do not include standpipes, vents, other piping systems, electrical conduit, outrigger beams, or counterweights. a. Located at 5434 Bowyer Court in Canal Winchester, Ohio: On or about March 13, 2019, an employee was performing siding work from a pump jack scaffold approximately twenty foot from the ground. The employer did not ensure that the Super Anchor roof anchor was fastened to the roof structure in accordance to the manufactures specifications, thereby exposing the employee to a fall hazard.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 A06
- Issued
- Mar 28, 2019
- Abate by
- Apr 17, 2019
- Penalty
- Initial $3,978 · Current $1,989 Reduced
General-duty citation text
29 CFR 1926.451(a)(6): Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory Appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section. a. Located at 5434 Bowyer Court in Canal Winchester, Ohio: On or about March 13, 2019, an employee was performing siding work from a pump jack scaffold approximately twenty foot from the ground. The employer did not ensure that the scaffold platform was leveled prior to performing the siding work at each elevation and pump jack poles were erected plumb to safely support the load of the scaffold platform. The condition of the scaffold exposed the employee to a fall hazard in the event of a scaffold shift or collapse.
Recent events (2)
- · I (S) $1989
- · Z (S) $3978
1926.452 J02
- Issued
- Mar 28, 2019
- Abate by
- Apr 17, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(j)(2): Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled. a. Located at 5434 Bowyer Court in Canal Winchester, Ohio: On or about March 13, 2019, an employee was performing siding work from a pump jack scaffold approximately twenty foot from the ground. The employer did not ensure that the pump jack poles were secured at the bottom to prevent from displacement, thereby exposing the employee to a fall hazard in the event of a scaffold shift or collapse.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 238170)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343849329.