CONCORD, NH —
OSHA Inspection: HASCALL & HALL INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HASCALL & HALL INC. in 15 PITMAN STREET, CONCORD, NH 03301 (NAICS 238140). OSHA activity number 343849675.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HASCALL & HALL INC.
- Site address
- 15 PITMAN STREET
- City
- CONCORD
- State
- NH
- ZIP
- 03301
- Mailing
- P.O. BOX 1838, PORTLAND, ME 04104
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 25
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 A06
- Issued
- Apr 30, 2019
- Penalty
- Initial $4,774 · Current $2,400 Reduced
General-duty citation text
29 CFR 1926.451(a)(6): Scaffolds designed by a qualified person were not constructed in accordance with that design: Roof - The Hi-Lo swing staging outrigger was not erected in accordance with the manufacturer's instructions.
Recent events (3)
- — F (S) $2400
- — C (S) $4774
- — Z (S) $4774
1926.451 D03 IV
- Issued
- Apr 30, 2019
- Penalty
- Initial $5,304 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(d)(3)(iv): Counterweights were not secured by mechanical means to the outrigger beams to prevent accidental displacement: Roof - The counterweights on the Hi-Lo outrigger beams were not secured in place.
Recent events (3)
- — F (S) $0
- — C (S) $5304
- — Z (S) $5304
1926.451 D02
- Issued
- Apr 30, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(d)(2): Suspension scaffold outrigger beams were not restrained to prevent movement: Roof - The tie back ropes were loose and not secured to the outriggers.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.451 D03 VII
- Issued
- Apr 30, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(d)(3)(vii): Tiebacks were not equivalent in strength to the suspension ropes: Roof - The rope tiebacks on the outriggers were not the same strength as the 3/8" wire rope on the staging.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.501 B01
- Issued
- Apr 30, 2019
- Abate by
- May 6, 2019
- Penalty
- Initial $4,774 · Current $2,400 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: Roof - Employee's were exposed to a fall hazard while working on the roof without any fall protection.
Recent events (3)
- — F (S) $2400
- — C (S) $4774
- — Z (S) $4774
1926.502 D15
- Issued
- Apr 30, 2019
- Abate by
- May 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment were not independent of any anchorage being used to support or suspend platforms and capable of supporting at least 5,000 pounds per employee attached, or were not designed, installed and used: Roof - Employees personal fall protection was anchored to an inadequate anchor point.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.502 D18
- Issued
- Apr 30, 2019
- Abate by
- May 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(18): body belts, harnesses and/or components of a personal fall arrest system were used for hoisting materials. Roof - Parapet Hooks for swing staging rigging were used for fall protection anchors.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at Hascall & Hall INC.
View Hascall & Hall INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343849675.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.