NORTH EAST, PA ·
OSHA Inspection: PAUL E. SEYMOUR TOOL & DIE, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PAUL E. SEYMOUR TOOL & DIE, LLC in 11416 WILSON ROAD, NORTH EAST, PA 16428 (NAICS 332710). OSHA activity number 343849881.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PAUL E. SEYMOUR TOOL & DIE, LLC
- Site address
- 11416 WILSON ROAD
- City
- NORTH EAST
- State
- PA
- ZIP
- 16428
- Mailing
- 11416 WILSON ROAD, NORTH EAST, PA 16428
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 16
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.37 A02
- Issued
- Apr 2, 2019
- Penalty
- Initial $1,642 · Current $1,149 Reduced
General-duty citation text
29 CFR 1910.37(a)(2): Exit routes were not arranged so that employees did not have to travel toward a high hazard area, unless the path of travel was effectively shielded from the high hazard area by suitable partitions or other physical barriers: A.) Paul E. Seymour Tool & Die, LLC, 11416 Wilson Road, North East, PA 16428, south side of the structure, hallway area between office area and shop area, on or about March 14, 2019 and times prior thereto: Two acetylene cylinders and one oxygen cylinder were located within the exit route.
Recent events (2)
- · I (S) $1149.4
- · Z (S) $1642
1910.219 D01
- Issued
- Apr 2, 2019
- Abate by
- Apr 26, 2019
- Penalty
- Initial $2,576 · Current $1,803 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): A.) Paul E. Seymour Tool & Die, LLC, 11416 Wilson Road, North East, PA 16428, shop area, east side of the structure, on or about March 14, 2019 and times prior thereto: Employees utilize the Roll-in Band Saw to cut parts including, but not limited to, support rings. The power transmission belt and pulley system on the Roll-in Band was not guarded. The power transmission belt and pulley system was within 4-feet of the floor surface.
Recent events (2)
- · I (S) $1803.2
- · Z (S) $2576
1910.212 A01
- Issued
- Apr 2, 2019
- Abate by
- Apr 26, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: A.) Paul E. Seymour Tool & Die, LLC, 11416 Wilson Road, North East, PA 16428, shop area, east side of the structure, on or about March 14, 2019 and times prior thereto: Employees utilize the Roll-in Band Saw to cut parts including, but not limited to, support rings. A one-inch portion of the band saw blade was exposed on the return side of the band saw.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 F02
- Issued
- Apr 2, 2019
- Abate by
- Apr 26, 2019
- Penalty
- Initial $1,932 · Current $1,352 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: A.) Paul E. Seymour Tool & Die, LLC, 11416 Wilson Road, North East, PA 16428, shop area, south side of the structure, right breaker panel box, on or about March 14, 2019 and times prior thereto: Employees were accessing and operating circuit breakers that operate equipment including, but not limited to, the HAAS CNC machines. Breakers #1, #3 and #5 were not identified as to their function and purpose. B.) Paul E. Seymour Tool & Die, LLC, 11416 Wilson Road, North East, PA 16428, shop area, south side of the structure, left breaker panel box, on or about March 14, 2019 and times prior thereto: Employees were accessing and operating circuit breakers that operate equipment including, but not limited to, overhead lighting. Breakers within the circuit breaker box were not identified as to their function and purpose.
Recent events (2)
- · I (S) $1352.4
- · Z (S) $1932
1910.304 F01 VIII
- Issued
- Apr 2, 2019
- Abate by
- Apr 26, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(f)(1)(viii): Circuit breakers used as switches in 120-volt and 277-volt, fluorescent lighting circuits were not listed and marked "SWD": A.) Paul E. Seymour Tool & Die, LLC, 11416 Wilson Road, North East, PA 16428, shop area, south side the structure, on or about March 14, 2019 and times prior thereto: Employees were operating circuit breakers to turn on/off overhead florescent lighting fixtures on a daily basis. The circuit breakers were not switch-duty circuit breakers.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.37 A04
- Issued
- Apr 2, 2019
- Abate by
- Apr 26, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: A.) Paul E. Seymour Tool & Die, LLC, 11416 Wilson Road, North East, PA 16428, front exit door at office area, south side the structure, on or about March 14, 2019 and times prior thereto: The electrically powered exit sign was not illuminated.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Paul E. Seymour Tool & DIE, LLC
View Paul E. Seymour Tool & DIE, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in PA
Source