Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PUMPING SOLUTIONS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PUMPING SOLUTIONS, INC. in 206 THRU-WAY PARK ROAD, BROUSSARD, LA 70518 (NAICS 332999). OSHA activity number 343853511.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pumping Solutions, INC. — free Get an email when a new federal OSHA severe-injury report for Pumping Solutions, INC. is published. One employer, no account, unsubscribe in one click.
Site address
206 THRU-WAY PARK ROAD
City
BROUSSARD
State
LA
ZIP
70518
Mailing
206 THRU-WAY PARK ROAD, BROUSSARD, LA 70518
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
60
Ownership type
A

3 citations on file for this inspection.

1910.179 J03

Serious Gravity 5 2 instances 1 exposed
Issued
Apr 15, 2019
Penalty
Initial $6,763 · Current $4,058 Reduced
29 CFR 1910.179(j)(3): Complete inspections of the crane was not being performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section:  On or about March 13, 2019 at ProFlow Pumping Solutions the employer failed to conduct periodic inspections of the chain hoist. Employees use the hoist daily if not every other day to move small parts 100/200 pounds.    Instance 1) Jet 1 ton, S/N 97550129  Instance 2) Jet ½ ton, S/N 120504081
Recent events (2)
  • — I (S) $4057.8
  • — Z (S) $6763

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 15, 2019
Abate by
Apr 29, 2019
Penalty
Initial $6,630 · Current $3,978 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by the chuck and parts being machined.  On or about March 13, 2019 at ProFlow Pumping Solutions the employer failed to ensure that the Kingston lathe, Model HD 22/20, S/N CH13001, had chuck guard. Employees use the lathe approximately three times per week.
Recent events (2)
  • — I (S) $3978
  • — Z (S) $6630

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 15, 2019
Penalty
Initial $3,381 · Current $2,029 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws.   On or about March 12. 2019 at Pro Glow Pumping Solutions the employer failed to ensure that a Dewalt grinder (Model DW827, S/N 63300) had adequate strain relief. Employee(s) were using the grinder to buff out parts.
Recent events (2)
  • — I (S) $2028.6
  • — Z (S) $3381

View Pumping Solutions, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343853511.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.