Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: O.G. CONSTRUCTION COMPANY, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of O.G. CONSTRUCTION COMPANY, LLC in 1314 W. EXPRESS WAY 83, PALMVIEW, TX 78572 (NAICS 237110). OSHA activity number 343855565.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch O.G. Construction Company, LLC — free Get an email when a new federal OSHA severe-injury report for O.G. Construction Company, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1314 W. EXPRESS WAY 83
City
PALMVIEW
State
TX
ZIP
78572
Mailing
222 W. UNIVERSITY DRIVE, EDINBURG, TX 78539
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.651 C02

Other-than-serious 1 instance 1 exposed
Issued
Jun 14, 2019
Penalty
Initial $7,293 · Current $3,719 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:    Employees conducted utility and sewer line operations in an excavation and were not provided a safe means of egress from the trench box, in that the ladder being used had damaged rungs.
Recent events (3)
  • — F (O) $3719.4
  • — C (S) $7293
  • — Z (S) $7293

1926.651 J02

Other-than-serious 1 instance 1 exposed
Issued
Jun 14, 2019
Penalty
Initial $10,210 · Current $3,719 Reduced
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:    Employees conducted utility and sewer line operations in an excavation and were not protected from stuck-by or engulfment hazards from spoil material which was not kept two feet or more from the trench.
Recent events (3)
  • — F (O) $3719.4
  • — C (S) $10210
  • — Z (S) $10210

1926.652 E01 I

Other-than-serious 1 instance 1 exposed
Issued
Jun 14, 2019
Abate by
Jul 10, 2019
Penalty
Initial $7,293 · Current $3,719 Reduced
29 CFR 1926.652(e)(1)(i): Members of support systems shall be securely connected together to prevent sliding, falling, kickouts, or other predictable failure.    Employees conducted underground sewer-line installation in an excavation where the trench box had missing trench box pins and keepers. Employees were exposed to struck-by and engulfment hazards.
Recent events (3)
  • — F (O) $3719.4
  • — C (S) $7293
  • — Z (S) $7293

View O.G. Construction Company, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343855565.