OSHA Inspection: CASE WESTERN RESERVE UNIVERSITY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CASE WESTERN RESERVE UNIVERSITY in A. W. SMITH BUILDING 2128 ADELBERT ROA 5TH FLOOR PENTHOUSE, CLEVELAND, OH 44106 (NAICS 611310). OSHA activity number 343857256.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Case Western Reserve University — free Get an email when a new federal OSHA severe-injury report for Case Western Reserve University is published. One employer, no account, unsubscribe in one click.
Site address
A. W. SMITH BUILDING 2128 ADELBERT ROA 5TH FLOOR PENTHOUSE
City
CLEVELAND
State
OH
ZIP
44106
Mailing
2220 CIRCLE DRIVE SERVICE BUILDING 1ST FLOOR, CLEVELAND, OH 44106
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
611310
Employees
90
Ownership type
A

4 citations on file for this inspection.

1910.147 C06 I

Deleted Serious Gravity 10 1 instance 9 exposed
Issued
May 6, 2019
Abate by
May 24, 2019
Penalty
Initial $13,260 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  On or about March 18, 2019, the employer failed to conduct a periodic inspection of the energy control procedure at least annually when employees exposed to machine hazards associated with high moving parts and in-going nip points and electrical energy sources performed lock out/tag out on various equipment throughout the facility including, but not limited to, the motor and pulley driving Fan 29.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13260

1910.147 D

Serious Gravity 10 1 instance 9 exposed
Issued
May 6, 2019
Abate by
May 24, 2019
Penalty
Initial $0 · Current $7,956
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):    On or about March 18, 2019, employees who conducted servicing and maintenance activities on the pulley belt driving Fan 29 including, but not limited to, changing the belt, were exposed to mechanical hazards associated with high moving parts and in-going nip points and electrical energy sources. The employer failed to implement energy control application steps as the machine was not prepared for shutdown [(d)(1)] or shut down or turned off to perform the servicing work [(d)(2)]. As a result, the remaining applicable energy control elements involving machine isolation [(d)(3)], LOTO device application[(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
  • — I (S) $7956
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 1 instance 9 exposed
Issued
May 6, 2019
Abate by
May 24, 2019
Penalty
Initial $9,472 · Current $5,683 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    a. On or about March 18, 2019, the employer failed to guard pulleys with moving parts less than seven feet from the floor. Employees who lock out the pulley driving the fan for "Room 203" to perform maintenance on the belt are exposed to amputation hazards when they have to access the cord and plug or switch on the unguarded front side of the pulleys.    b. On or about March 18, 2019, the employer failed to guard pulleys with moving parts less than seven feet from the floor. Employees who lock out the pulley driving the fan labeled "Toilet Exh." to perform maintenance on the belt are exposed to amputation hazards when they have to access the cord and plug or switch on the unguarded front side of the pulley.
Recent events (2)
  • — I (S) $5683.2
  • — Z (S) $9472

1910.305 B02 I

Serious Gravity 5 1 instance 9 exposed
Issued
May 6, 2019
Abate by
May 24, 2019
Penalty
Initial $7,577 · Current $4,546 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    On or about March 18, 2019, the employer failed to ensure that all junction boxes were provided with covers approved for the purpose when a junction box housing the switch wiring for the "Toilet Exh." fan motor in the Penthouse level of the A. W. Smith building was left open.
Recent events (2)
  • — I (S) $4546.2
  • — Z (S) $7577