GOODING, ID —
OSHA Inspection: HATFIELD MANUFACTURING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HATFIELD MANUFACTURING, INC. in 1823 SHOESTRING ROAD, GOODING, ID 83330 (NAICS 423830). OSHA activity number 343857629.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HATFIELD MANUFACTURING, INC.
- Site address
- 1823 SHOESTRING ROAD
- City
- GOODING
- State
- ID
- ZIP
- 83330
- Mailing
- 1823 SHOESTRING ROAD, GOODING, ID 83330
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423830
- Employees
- 53
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jul 15, 2019
- Abate by
- Aug 8, 2019
- Penalty
- Initial $9,282 · Current $4,600 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On March 14, 2019 and times prior thereto; the employer did not ensure lock out tag out procedures were utilized when employees were allowed to service and perform maintenance and die changes on machinery including but not limited to press brakes. Note: Abatement certification and documentation are required for this item.
Recent events (2)
- — I (S) $4600
- — Z (S) $9282
1910.147 C06 I
- Issued
- Jul 15, 2019
- Abate by
- Aug 8, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) On March 14, 2019 and times prior thereto; the employer exposed employees to potential hazardous energies in that the employees were allowed to service and perform maintenance and die changes on machinery including but not limited to press brakes. Note: Abatement certification and documentation are required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Jul 15, 2019
- Abate by
- Aug 8, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: (a) On March 14, 2019 and times prior thereto; the employer exposed employees to potential hazardous energies in that the employees were allowed to service and perform maintenance and die changes on machinery including but not limited to press brakes. Note: Abatement certification and documentation are required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Jul 15, 2019
- Abate by
- Aug 8, 2019
- Penalty
- Initial $6,630 · Current $3,400 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Main Shop, on and before March 14, 2019; the AccurPress 509006 press brake did not have guarding. (b) Main Shop, on and before March 14, 2019; the AccurPress 519012 press brake did not have guarding. Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $3400
- — Z (S) $6630
1910.303 F02
- Issued
- Jul 15, 2019
- Abate by
- Jul 25, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) Main Building, on or about March 14, 2019; the breaker was not labeled for its purpose. Note: Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Hatfield Manufacturing, INC.
View Hatfield Manufacturing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423830)
More inspections in ID