Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: CHEP SERVICES LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CHEP SERVICES LLC in 6600 NEW VENTURE GEAR DRIVE, EAST SYRACUSE, NY 13057 (NAICS 321920). OSHA activity number 343863544.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Chep Services LLC for free Get an email when a new federal OSHA severe-injury report for Chep Services LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CHEP SERVICES LLC
Site address
6600 NEW VENTURE GEAR DRIVE
City
EAST SYRACUSE
State
NY
ZIP
13057
Mailing
6600 NEW VENTURE GEAR DRIVE, EAST SYRACUSE, NY 13057
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
26
Ownership type
Private (A)

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 9, 2019
Penalty
Initial $4,830 · Current $3,220 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts:    a)  Maintenance Cage, on or about 3/20/19:  Rotating chuck on a Ryobi drill press was not guarded.
Recent events (2)
  • · I (S) $3220
  • · Z (S) $4830

1910.242 A

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 9, 2019
Penalty
Initial $4,830 · Current $3,220 Reduced
29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition:    a)  Sort Machine 600, on or about 3/20/19:  Compressed air wand used for cleaning purposes had a missing dead man trigger switch.
Recent events (2)
  • · I (S) $3220
  • · Z (S) $4830

1910.242 B

Serious Gravity 1 2 instances 2 exposed
Issued
Apr 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  a)  Sort Machine 600, on or about 3/20/19:  Compressed air wand used for cleaning purposes measured >100 psi.  b)  Repair Line, on or about 3/2/19:  Compressed air wand used for cleaning purposes measured >100 psi.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G01 IV A

Other-than-serious 1 instance 1 exposed
Issued
Apr 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a)  Maintenance Cage, on or about 3/20/19:  A power strip providing current to a cutoff saw and a grinder was attached to a workbench and being used as permanent wiring.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Chep Services LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343863544.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.