TUNKHANNOCK, PA —
OSHA Inspection: OSO WASH LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of OSO WASH LLC in 27 SR 1006 ALDOVIN ROAD, TUNKHANNOCK, PA 18657 (NAICS 213112). OSHA activity number 343867644.
Where did this inspection happen?
- Establishment
- OSO WASH LLC
- Site address
- 27 SR 1006 ALDOVIN ROAD
- City
- TUNKHANNOCK
- State
- PA
- ZIP
- 18657
- Mailing
- 27 SR 1006 ALDOVIN ROAD, TUNKHANNOCK, PA 18657
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 8
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.146 C05 II C
- Issued
- Abate by
- Penalty
- Initial $1932.00 · Current $1000.00 Reduced
X100
General-duty citation text
29 CFR 1910.146(c)(5)(ii)(C): Employees entered into permit spaces that met the conditions set forth in 29 CFR 1910.146(c)(5)(i) but before an employee entered the space, the internal atmosphere was not tested with a calibrated direct-reading instrument: a) Wash Bay, entrant entered vacuum box #280764, a permit required confined space, and the attendant performed air testing with a GasAlert detector which was not calibrated in accordance with the manufacturer criteria, and was not challenged with a daily bump test per manufacturer criteria, on or about, March 20, 2019. b) Wash Bay, entrant entered vacuum trucks including Holcombe truck #28, a permit required space, and the attendant performed air testing with a GasAlert detector which was not calibrated in accordance with the manufacturer criteria, and was not challenged with a daily bump test per manufacturer criteria, on or about, March 20, 2019. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1000
- — Z (S) $1932
1910.146 H02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
X100
General-duty citation text
29 CFR 1910.146(h)(2): The employer did not ensure that all authorized entrants properly used equipment as required by 29 CFR 1910.146(d)(4)(a): a) Wash Bay, entrant entered vacuum box #280764, a permit required confined space, and the attendant who performed the air monitoring was not aware that the monitoring instrument required either a daily full calibration or a daily functional challenge with bump gas in order to ensure that the instrument was functioning within normal parameters, on or about, March 20, 2019. b) Wash Bay, entrant entered vacuum trucks including Holcombe truck #28, a permit required space, and the attendant who performed the air monitoring was not aware that the monitoring instrument required either a daily full calibration or a daily functional challenge with bump gas in order to ensure that the instrument was functioning within normal parameters, on or about, March 20, 2019. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 K03 I
- Issued
- Abate by
- Penalty
- Initial $1932.00 · Current $950.00 Reduced
X100
General-duty citation text
29 CFR 1910.146(k)(3)(i): Each authorized entrant did not use a chest or full body harness, with a retrieval line attached at the center of the entrant's back near shoulder level, or above the entrant's head: a) Wash Bay, entrant entered vacuum box #280764, a permit required confined space, and did not wear a body harness which was attached to a retrieval line which had the end located outside of the space, on or about, March 20, 2019. b) Wash Bay, entrant entered vacuum trucks including Holcombe truck #28, a permit required space, and did not wear a body harness which was attached to a retrieval line which had the end located outside of the space, on or about, March 20, 2019. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $950
- — Z (S) $1932
1910.146 F12
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
1910.146(f)(12): Permit space entry permits did not contain the communication procedures used by authorized entrants and attendants to maintain contact during the entry; a) Wash Bay, permit templates used to review procedures and record compliance with them, did not have a section which addressed the communication procedures to be used by entrants and attendants to maintain contact throughout the duration of the entry, on or about, March 20, 2019. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 213112)
SEILING, OK—2026-06-26
GORE ENERGY
SCIO, OH—2026-06-25
AMPRO WELL SERVICES, LLC
MIDLAND, TX—2026-06-23
JAT PARTNER LOGISTICS LLC
STUART, OK—2026-06-18
HEARTLAND ENERGY SOLUTIONS, LLC
GARDEN CITY, TX—2026-06-17
EBENEZER COMPANIES LLC
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343867644.