CHENANGO FORKS, NY ·
OSHA Inspection: STILLWATER CHILDREN'S CENTER
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STILLWATER CHILDREN'S CENTER in 638 SQUIRREL HILL ROAD, CHENANGO FORKS, NY 13746 (NAICS 623990). OSHA activity number 343869046.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STILLWATER CHILDREN'S CENTER
- Site address
- 638 SQUIRREL HILL ROAD
- City
- CHENANGO FORKS
- State
- NY
- ZIP
- 13746
- Mailing
- 638 SQUIRREL HILL ROAD, CHENANGO FORKS, NY 13746
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 623990
- Employees
- 45
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.146 C04
- Issued
- Jun 26, 2019
- Abate by
- Jul 31, 2019
- Penalty
- Initial $11,366 · Current $4,700 Reduced
General-duty citation text
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146: a. On the facility property, on or about 3/21/19: An employee must enter an in ground vault in order to provide maintenance for the water system. The space has been designated a confined space by the employer. The employer has not written nor developed a confined space entry program which meets the requirements of the standard. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $4700
- · C (S) $11366
- · Z (S) $11366
1910.146 C05 II C
- Issued
- Jun 26, 2019
- Abate by
- Jul 31, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(5)(ii)(C): Before an employee entered a space, the internal atmosphere was not tested with a calibrated direct-reading instrument for oxygen, flammable gases and vapors and potential toxic air contaminants: a. On the facility property, on or about 3/21/19: An employee is required to enter an in ground vault designated as a confined space to perform maintenance on the water system and test the backup generator. Prior to entry, the employee did not test the internal atmosphere of the space. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $0
- · C (S) $0
- · Z (S) $0
1910.146 G01
- Issued
- Jun 26, 2019
- Abate by
- Jul 22, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146: a. On the facility property, on or about 3/21/19: An employee was required to enter an in ground vault in order to provide maintenance for the water system and test the backup generator. The employer had not provided training to the employee with regard to working safely within a confined space. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $0
- · C (S) $0
- · Z (S) $0
1910.303 G02 I
- Issued
- Jun 26, 2019
- Abate by
- Jul 8, 2019
- Penalty
- Initial $5,683 · Current $2,300 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a. Within the facility electrical room, on or about 3/21/19: An electrical circuit breaker panel was missing a blank thereby exposing employees to live electrical parts. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $2300
- · C (S) $5683
- · Z (S) $5683
More inspections in this industry (NAICS 623990)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343869046.