PALM BEACH SHORES, FL ·
OSHA Inspection: DANIELLO & ASSOCIATES INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DANIELLO & ASSOCIATES INC. in 125 S. OCEAN AVENUE, PALM BEACH SHORES, FL 33404 (NAICS 238390). OSHA activity number 343870333.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DANIELLO & ASSOCIATES INC.
- Site address
- 125 S. OCEAN AVENUE
- City
- PALM BEACH SHORES
- State
- FL
- ZIP
- 33404
- Mailing
- 2708 N AUSTRALIAN AVE SUITE 9 SUITE 9, WEST PALM BEACH, FL 33407
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238390
- Employees
- 4
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1926.451 B01
- Issued
- Apr 11, 2019
- Abate by
- May 7, 2019
- Penalty
- Initial $6,630 · Current $4,001 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about March 18, 2019, at the back of the building located at 125 S. Ocean Avenue in Palm Beach Shores, Florida, an employee was chipping concrete from a scaffold platform that only had one plank, exposing him to a fall of approximately 17 feet.
Recent events (2)
- · I (S) $4000.8
- · Z (S) $6630
1926.451 C01
- Issued
- Apr 11, 2019
- Abate by
- May 7, 2019
- Penalty
- Initial $6,630 · Current $4,001 Reduced
General-duty citation text
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph: On or about March 18, 2019, at the back of the building located at 125 S. Ocean Avenue in Palm Beach Shores, Florida, an employee was chipping concrete from a scaffold that measured over 20 feet in height and it had not been tied to the building, exposing him to a fall of approximately 17 feet.
Recent events (2)
- · I (S) $4000.8
- · Z (S) $6630
1926.451 E04 I
- Issued
- Apr 11, 2019
- Abate by
- May 7, 2019
- Penalty
- Initial $6,630 · Current $4,001 Reduced
General-duty citation text
29 CFR 1926.451(e)(4)(i): A stairrail consisting of a toprail and a midrail was not provided on each side of each scaffold stairway: On or about March 18, 2019, at the back of the building located at 125 S. Ocean Avenue in Palm Beach Shores, Florida, an employee used a scaffold stairway that did not have a stair rail on each side, exposing him to a fall of approximately 17 feet.
Recent events (2)
- · I (S) $4000.8
- · Z (S) $6630
1926.451 E04 VIII
- Issued
- Apr 11, 2019
- Abate by
- May 7, 2019
- Penalty
- Initial $6,630 · Current $4,001 Reduced
General-duty citation text
29 CFR 1926.451(e)(4)(viii): A landing platform at least 18 inches (45.7 cm) wide by at least 18 inches (45.7 cm) long was not provided at each level: On or about March 18, 2019, at the back of the building located at 125 S. Ocean Avenue in Palm Beach Shores, Florida, an employee used a scaffold stairway that did not have a landing platform at the end of each scaffold stairway, exposing him to a fall of approximately 17 feet.
Recent events (2)
- · I (S) $4000.8
- · Z (S) $6630
1926.451 G01 VII
- Issued
- Apr 11, 2019
- Abate by
- May 7, 2019
- Penalty
- Initial $6,630 · Current $4,001 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: On or about March 18, 2019, at the back of the building located at 125 S. Ocean Avenue in Palm Beach Shores, Florida, an employee was chipping concrete from a scaffold platform that did not have guard rails, exposing him to a fall of approximately 17 feet.
Recent events (2)
- · I (S) $4000.8
- · Z (S) $6630
1926.451 F07
- Issued
- Apr 11, 2019
- Abate by
- May 7, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration; Such activities were not performed only by experienced and trained employees selected for such work by the competent person: On or about March 18, 2019, at the back of the building located at 125 S. Ocean Avenue in Palm Beach Shores, Florida, the scaffold on which an employee was chipping concrete was not erected under the supervision of a competent person, exposing him to a fall of approximately 17 feet.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Daniello & Associates INC.
View Daniello & Associates INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238390)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343870333.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.