Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: RAM RECYCLING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RAM RECYCLING, INC. in 400 W MARQUETTE AVE, OAK CREEK, WI 53154 (NAICS 423930). OSHA activity number 343870713.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RAM Recycling, INC. for free Get an email when a new federal OSHA severe-injury report for RAM Recycling, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
RAM RECYCLING, INC.
Site address
400 W MARQUETTE AVE
City
OAK CREEK
State
WI
ZIP
53154
Mailing
400 W MARQUETTE AVE, OAK CREEK, WI 53154
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
22
Ownership type
Private (A)

5 citations on file for this inspection.

1910.28 B06 I

Other-than-serious 1 instance 3 exposed
Issued
Jul 25, 2019
Abate by
Oct 2, 2019
Penalty
Initial $5,304 · Current $2,652 Reduced
29 CFR 1910.28(b)(6)(i): Each employee less than 4 feet (1.2 m) above dangerous equipment was not protected from falling into or onto the dangerous equipment by a guardrail system or a travel restraint system, unless the equipment is covered or guarded to eliminate the hazard.    (a) At the worksite located at 400 W. Marquette Ave., Oak Creek, WI, the employer did not ensure employees were protected from falling into equipment such as a conveyor that fed a bailer machine, thereby exposing employees to crushing hazards and entanglement hazards.
Recent events (2)
  • · I (O) $2652
  • · Z (S) $5304

1910.212 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 25, 2019
Abate by
Aug 20, 2019
Penalty
Initial $1,932 · Current $1,160 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) At the worksite located at 400 W. Marquette Ave., Oak Creek, WI, the employer did not ensure an unwinder machine was guarded to prevent contact with rotating components, thereby exposing employees to entanglement hazards.
Recent events (2)
  • · I (S) $1160
  • · Z (S) $1932

1910.132 D01

Other-than-serious 1 instance 9 exposed
Issued
Jul 25, 2019
Abate by
Sep 11, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):  (a) At the worksite located at 400 W. Marquette Ave., Oak Creek, WI, the employer did not ensure a PPE hazard assessment was conducted.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 G01 I A

Other-than-serious 1 instance 9 exposed
Issued
Jul 25, 2019
Abate by
Jul 31, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:  (a) At the worksite located at 400 W. Marquette Ave., Oak Creek, WI, the employer did not ensure an electric panel had adequate clearance in front of the unit, thereby exposing employees to potential electrical hazards and preventing immediate access to panels.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 B01 II

Other-than-serious 1 instance 9 exposed
Issued
Jul 25, 2019
Abate by
Aug 20, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:  (a) At the worksite located at 400 W. Marquette Ave., Oak Creek, WI, the employer did not ensure an electric panel had a latch that could properly close the access door.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343870713.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.