MILTON, PA —
OSHA Inspection: KEYSTONE SPORTING ARMS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KEYSTONE SPORTING ARMS LLC in 155 SODOM RD., MILTON, PA 17847 (NAICS 332994). OSHA activity number 343876041.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KEYSTONE SPORTING ARMS LLC
- Site address
- 155 SODOM RD.
- City
- MILTON
- State
- PA
- ZIP
- 17847
- Mailing
- 155 SODOM RD., MILTON, PA 17847
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332994
- Employees
- 50
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.217 B07 V A
- Issued
- Jul 2, 2019
- Abate by
- Aug 19, 2019
- Penalty
- Initial $2,685 · Current $1,880 Reduced
General-duty citation text
29 CFR 1910.217(b)(7)(v)(a): Each two-hand control for single stroke operations on mechanical power press(es) using part revolution clutches was not protected against unintended operation: a) Warehouse: The two hand controls on the Niagara E-60 part revolution mechanical power press were not protected against unintentional operation, as observed on or about April 24, 2019. Abatement Certification Required.
Recent events (2)
- — I (S) $1879.5
- — Z (S) $2685
1910.147 C06 I
- Issued
- Jul 2, 2019
- Abate by
- Aug 19, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Maintenance: The employer did not conduct a periodic inspection of the energy control procedures for equipment including, but not limited to, processing equipment, mechanical power presses and dust collection system at least annually to ensure that the procedures and the requirements of this standard were being followed, on or about April 24, 2019. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Jul 2, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Assembly area: Relocatable power taps (RPTs) were not used in accordance with instructions in the listing or labeling in that RPTs were connected in series (daisy chained) and not directly connected to a permanently installed receptacle (connected by extension cord), as observed on or about March 25, 2019. Abatement Observed During Inspection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Keystone Sporting Arms LLC
View Keystone Sporting Arms LLC's full OSHA safety record →
More inspections in this industry (NAICS 332994)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343876041.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.