WESLEY CHAPEL, FL —
OSHA Inspection: CRS BUILDING CORPORATION
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of CRS BUILDING CORPORATION in PASCO COUNTY FIRE RESCUE STATION NO. 38, WESLEY CHAPEL, FL 33543 (NAICS 236220). OSHA activity number 343877569.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CRS BUILDING CORPORATION
- Site address
- PASCO COUNTY FIRE RESCUE STATION NO. 38
- City
- WESLEY CHAPEL
- State
- FL
- ZIP
- 33543
- Mailing
- 100 2ND AVE SOUTH SUITE 301-S, SAINT PETERSBURG, FL 33701
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 2
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.100 A
- Issued
- Sep 13, 2019
- Abate by
- Oct 9, 2019
- Penalty
- Initial $3,031 · Current $2,400 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) At the construction of Fire Station # 38 in Wesley Chapel, FL., the employees of West Coast Masonry Inc. were exposed to struck by hazards from falling objects while working under and around a scaffold system. The employees were not using hardhats as observed on or about 03/21/2019.
Recent events (2)
- — I (S) $2400
- — Z (S) $3031
1926.451 C02
- Issued
- Sep 13, 2019
- Abate by
- Oct 9, 2019
- Penalty
- Initial $4,546 · Current $3,600 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a) At the construction of Fire Station # 38 in Wesley Chapel, FL., employees of West Coast Masonry Inc. installing bricks on masonry walls from a scaffold system were exposed to a fall hazard of approximately 6 feet and 4 inches in that the scaffold legs, did not bear on base plates. As observed on or about 03/21/2019.
Recent events (2)
- — I (S) $3600
- — Z (S) $4546
1926.451 E01
- Issued
- Sep 13, 2019
- Abate by
- Oct 9, 2019
- Penalty
- Initial $3,789 · Current $2,600 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) At the construction of Fire Station # 38 in Wesley Chapel, FL., where employees of West Coast Masonry Inc. installing bricks on masonry walls from a scaffold system were exposed to a fall hazard of 13 feet and 4 inches in that no ladders were provided as a means of access and egress to and from the scaffold platforms. As observed on 03/21/2019.
Recent events (2)
- — I (S) $2600
- — Z (S) $3789
1926.451 F03
- Issued
- Sep 13, 2019
- Abate by
- Oct 9, 2019
- Penalty
- Initial $5,304 · Current $4,200 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) At the east side of building, employees of West Coast Masonry Inc. installing brick masonry walls from a two tiered scaffold system were exposed to a fall hazard of 13 feet and 4 inches in that the scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift. As observed on or about 03/21/2019. b) At the east side of construction of Fire Station # 38 in Wesley Chapel, FL., employees of West Coast Masonry Inc. installing bricks on masonry walls from a scaffold system were exposed to a fall hazard of 6 feet and 4 inches in that the scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift. As observed on or about 03/21/2019.
Recent events (2)
- — I (S) $4200
- — Z (S) $5304
1926.451 G01
- Issued
- Sep 13, 2019
- Abate by
- Oct 9, 2019
- Penalty
- Initial $5,304 · Current $4,200 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. a) At the construction of Fire Station # 38 in Wesley Chapel, FL., employees of West Coast Masonry Inc. installing bricks on masonry walls from a scaffold system were exposed to a fall hazard of approximately 13 feet and 4 inches in that there were no guardrails or personal fall arrest system to prevent a fall. As observed on or about 03/21/2019.
Recent events (2)
- — I (S) $4200
- — Z (S) $5304
1926.501 B03
- Issued
- Sep 13, 2019
- Abate by
- Oct 9, 2019
- Penalty
- Initial $5,304 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(3): Each employee in a hoist area was not protected from falling 6 feet (1.8 m) or more to lower levels by guardrail systems or personal fall arrest systems: a) At the construction of Fire Station # 38 in Wesley Chapel, FL., the employees of West Coast Masonry Inc. were walking and working on a section of the roof used for hoisting materials. The employees were exposed to a fall hazard of 10 feet in that there were no guardrails or personal fall arrest system to prevent a fall. On or about 03/21/2019.
Recent events (2)
- — I (S) $0
- — Z (S) $5304
More inspections at CRS Building Corporation