OSHA Inspection: BRIESS INDUSTRIES INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BRIESS INDUSTRIES INC in 37 SOUTH COLUMBIA ST, CHILTON, WI 53014 (NAICS 311213). OSHA activity number 343880936.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Briess Industries INC for free Get an email when a new federal OSHA severe-injury report for Briess Industries INC is published. One employer, no account, unsubscribe in one click.
Site address
37 SOUTH COLUMBIA ST
City
CHILTON
State
WI
ZIP
53014
Mailing
PO BOX 229, CHILTON, WI 53014
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311213
Employees
25
Ownership type
Private (A)

1 citation on file for this inspection.

1910.147 D

Serious Gravity 10 1 instance 1 exposed
Issued
May 31, 2019
Abate by
Jun 28, 2019
Penalty
Initial $13,260 · Current $7,956 Reduced
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:     On or about March 22, 2019, employee(s) were exposed to machine hazards associated with moving parts when they were engaged in servicing and maintenance activities on the Bin 17 auger conveyor.  The employer did not ensure that energy control application steps to control the electrical energy sources were implemented prior to allowing employees to clean inside the enclosed auger for Bin 17 to milling.  The machine was not shut down or turned off prior to engaging in this servicing and maintenance activity.        As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine servicing hazards.
Recent events (2)
  • · I (S) $7956
  • · Z (S) $13260