Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MAC CONSTRUCTION COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MAC CONSTRUCTION COMPANY, INC. in 2300 ELGIN STREET, RAPID CITY, SD 57703 (NAICS 236220). OSHA activity number 343881843.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MAC Construction Company, INC. — free Get an email when a new federal OSHA severe-injury report for MAC Construction Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2300 ELGIN STREET
City
RAPID CITY
State
SD
ZIP
57703
Mailing
4440 UNIVERSAL DRIVE, RAPID CITY, SD 57702
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.451 E08

Other-than-serious 1 instance 4 exposed
Issued
Jun 26, 2019
Abate by
Jul 23, 2019
Penalty
Initial $2,273 · Current $2,273
29 CFR 1926.451(e)(8): Direct access to or from another surface shall not be used when the scaffold is more than 14 inches (36 cm) horizontally and/or 24 inches (61 cm) vertically from the other surface:    (a)MAC Construction Company, Inc. @ 2300 Elgin Street, Rapid City, SD 57701: On or about and at times prior to March 21, 2019, the controlling and exposing employer did not ensure each employee and subcontractor employee was provided adequate access from scaffolding to a roof.  Employees were using a scaffold plank located on the second level of a mobile fabricated frame scaffolding system to gain access to a roof, which was located approximately 30 inches in height from the scaffold plank. Employees were using the scaffolding to access the roof to remove existing roof panels for steel stud installation on a roof without the use of fall protection system. Subcontractor employees were using the scaffolding to access the roof for steel stud installation. The condition exposed employees and subcontractor employees to a fall hazard of approximately 10 feet and 6 inches to the ground below.
Recent events (2)
  • — I (O) $2273
  • — Z (S) $2273

1926.451 E06 VI

Other-than-serious 1 instance 4 exposed
Issued
Jun 26, 2019
Abate by
Jul 23, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(6)(vi): 29 CFR 1926.451(e)(6)(vi): Integral prefabricated scaffold access frames did not have a maximum spacing between rungs of 16 3/4 inches (43 cm). Non-uniform rung spacing caused by joining end frames together is allowed, provided the spacing does not exceed 16 3/4 inches (43 cm):    (a)MAC Construction Company, Inc. @ 2300 Elgin Street, Rapid City, SD 57701: On or about and at times prior to March 21, 2019, the controlling and exposing employer did not ensure each employee and subcontractor employee was provided sufficient access due to inadequate ladder rung spacing on end-frames of a fabricated frame scaffolding system. The ladder rungs on the end-frames were measured at approximately 22.25 inches in vertical distance from the top of each rung. Employees were climbing the integrated ladder rungs on the end-frames to gain access to the roof. The condition exposed employees and subcontractor employees to a fall hazard while climbing the scaffolding to gain access to the roof.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.501 B01

Other-than-serious 1 instance 4 exposed
Issued
Jun 26, 2019
Abate by
Jul 23, 2019
Penalty
Initial $3,031 · Current $3,031
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:       (a)MAC Construction Company, Inc. @ 2300 Elgin Street, Rapid City, SD 57701: On or about and at times prior to March 21, 2019, the controlling and exposing employer did not ensure each employee and subcontractor employee on a walking/working surface having an unprotected side or edge which was six feet or more above a lower level was protected from falling by the use of a guardrail system, a safety net system or personal fall arrest system. Employees were engaged in removing roof panels for steel stud installation on an existing roof without the use of fall protection system. Subcontractors working on the roof were installing steel studs while exposed to a fall hazard. The condition exposed employees and subcontractor employees to a fall hazard of approximately 10 foot and 6 inches to the ground below.
Recent events (2)
  • — I (O) $3031
  • — Z (S) $3031

View MAC Construction Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343881843.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.