Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HARBOR FURNITURE MANUFACTURING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HARBOR FURNITURE MANUFACTURING, INC. in 27418 HWY 98 EAST, ELBERTA, AL 36530 (NAICS 337127). OSHA activity number 343885604.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Harbor Furniture Manufacturing, INC. — free Get an email when a new federal OSHA severe-injury report for Harbor Furniture Manufacturing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
27418 HWY 98 EAST
City
ELBERTA
State
AL
ZIP
36530
Mailing
P.O. DRAWER 340, ELBERTA, AL 36530
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337127
Employees
80
Ownership type
A

13 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 18, 2019
Abate by
Jul 30, 2019
Penalty
Initial $5,304 · Current $3,500 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of being struck-by fragments of polyvinyl Chloride (PVC) plastic pipe in the event that the PVC plastic pipe ruptured:     a)  Maintenance Shop; On or about March 27, 2019 and at times prior thereto the employer exposed employees to the hazard of being struck-by fragments of Polyvinyl Chloride (PVC) plastic pipe in the event that the PVC plastic pipe ruptured:  Shop Areas - PVC plastic piping was used in exposed above ground locations to transport compressed air at 90 psi exposing employees to struck-by hazards from shards of PVC if the pipe ruptures or explodes.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $5304

1910.147 C07 I

Serious Gravity 5 1 instance 80 exposed
Issued
Jul 18, 2019
Abate by
Jul 30, 2019
Penalty
Initial $6,630 · Current $3,400 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program was understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired by employees.    a)  All employees; On or about March 27, 2019 and at times prior thereto the employer exposed employees to potential hazardous energies in that employees were allowed to work on equipment without first being trained to ensure those employees had the knowledge and skills for the safe application, usage, and removal of energy controls. The employer failed to provide affected and authorized lockout tagout training.
Recent events (2)
  • — I (S) $3400
  • — Z (S) $6630

1910.147 F03 II D

Serious Gravity 5 2 instances 4 exposed
Issued
Jul 18, 2019
Abate by
Jul 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment:  a)  Main production area; On or about March 27, 2019 and at times prior thereto the employer exposed employees to potential hazardous energies in that employees were allowed to work on the Time Saver together without all employees applying a personal lockout device on the energy control lockout point.  b) Main production area; On or about March 27, 2019 and at times prior thereto the employer exposed employees to potential hazardous energies in that employees were allowed to work on the Dust Collector together without all employees applying a personal lockout device on the energy control lockout point.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 18, 2019
Abate by
Jul 30, 2019
Penalty
Initial $6,630 · Current $3,400 Reduced
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:   a)  Main Production; On or about March 27, 2019 and at times prior thereto the employer exposed employees to amputation hazards in that employees were allowed to operate a Delta table saw without a guard in place that had an automatically adjusting hood and completely enclosed the portion of the saw above the table and above the material being cut as required by the regulation.
Recent events (2)
  • — I (S) $3400
  • — Z (S) $6630

1910.213 C02

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 18, 2019
Abate by
Jul 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator:   a)  Production Area; On or about March 27, 2019 and at times prior thereto the employer exposed employees to struck-by hazards in that employees were allowed to use a Delta table saw with the spreader bar not installed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 C03

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 18, 2019
Abate by
Jul 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:   a)  Production Area; On or about March 27, 2019 and at times prior thereto the employer exposed employees to struck-by hazards in that employees were allowed to use a Delta table saw with the kickback fingers not installed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 A01

Serious Gravity 5 1 instance 80 exposed
Issued
Jul 18, 2019
Abate by
Jul 30, 2019
Penalty
Initial $4,508 · Current $3,400 Reduced
29 CFR 1910.215(a)(1): Abrasive wheel(s) used on grinding machinery were not used with safety guard(s):   a)  Maintenance Shop; On or about March 27, 2019 and at times prior thereto the employer exposed employees to caught - in hazards in that employees were allowed to operate a bench grinder with the side guards removed.
Recent events (2)
  • — I (S) $3400
  • — Z (S) $4508

1910.253 B04 III

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 18, 2019
Abate by
Jul 30, 2019
Penalty
Initial $5,636 · Current $3,400 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour:        a)  Maintenance Shop; On or about March 27, 2019 and at times prior thereto the employer exposed employees to fire hazards in that employees were allowed to walk and work in the same area where oxygen compressed gas cylinders and fuel (acetylene) compressed gas cylinders were stored together without a noncombustible barrier as required by the standard.
Recent events (2)
  • — I (S) $3400
  • — Z (S) $5636

1910.253 B02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 18, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(ii):   Cylinders were not stored in areas to ensure that the cylinders would not be knocked over:   a)  Maintenance Shop; On or about March 27, 2019 and at times prior thereto the employer exposed his employees to compressed gas hazards in that compressed gas cylinders were stored in areas where they could be knocked over.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 18, 2019
Abate by
Jul 30, 2019
Penalty
Initial $4,508 · Current $3,400 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed.    a)  Glue Roller; On or about March 27, 2019 and at times prior thereto the employer exposed employees to electrical and fire hazards in that unused openings in cabinets, boxes, and fittings were not effectively closed.
Recent events (2)
  • — I (S) $3400
  • — Z (S) $4508

1910.146 C01

Other-than-serious 1 instance 3 exposed
Issued
Jul 18, 2019
Abate by
Jul 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:   a) Yard and production floor; On or about March 27, 2019 and at times prior thereto the employer potentially exposed employees to confined space hazards in that the employer failed to evaluate the workplace to determine if they had any confined spaces and if those spaces were permit required. The employer has a dust collection silo and potentially other confined spaces which have not been evaluated as to permit required or not.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B02

Other-than-serious 1 instance 2 exposed
Issued
Jul 18, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:     a)  Resin Area; On or about March 27, 2019February 12, 2013 and at times prior thereto the employer exposed employees to electrical hazards in that employees were required to use a 120 VAC electrical outlet constructed from a 4  x 4 metal box with pre-punched knockouts on a flexible cord. The electrical equipment is not listed or labeled for that use.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV D

Other-than-serious 1 instance 80 exposed
Issued
Jul 18, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were attached to building surfaces:  a) Old Shipping Area; On or about march 27, 2019 and at times prior thereto the employer exposed employees to electrical hazards in that employees were allowed to walk and work around a temporary flexible cord that was attached to the building and hung from the ceiling in lieu of permanent fixed wiring.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Harbor Furniture Manufacturing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343885604.