OSHA Inspection: MERRICK ENGINEERING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MERRICK ENGINEERING in 7325 IMPERIEL DR., WACO, TX 76712 (NAICS 326199). OSHA activity number 343893509.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Merrick Engineering — free Get an email when a new federal OSHA severe-injury report for Merrick Engineering is published. One employer, no account, unsubscribe in one click.
Establishment
MERRICK ENGINEERING
Site address
7325 IMPERIEL DR.
City
WACO
State
TX
ZIP
76712
Mailing
7325 IMPERIEL DR., WACO, TX 76712
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
60
Ownership type
A

3 citations on file for this inspection.

1910.101 B

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 5, 2019
Penalty
Initial $4,508 · Current $2,705 Reduced
29 CFR 1910.101(b): 29 CFR 1910.101(b):  Section 3.4.4, Compressed Gas Association Pamphlet P11965, as adopted by 29 CFR 1910.101(b): Compressed gas cylinder(s) not in use were not properly supported to prevent them from being knocked over.   In the maintenance shop, three nitrogen compressed gas cylinders were not chained or secured from falling exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $2704.8
  • — Z (S) $4508

1910.215 B09

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 5, 2019
Penalty
Initial $3,381 · Current $2,029 Reduced
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel.     In the maintenance shop, the employer did not ensure adjustable tongue guards were installed prior to operating the bench grinder exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $2028.6
  • — Z (S) $3381

1910.303 E01 II

Other-than-serious 1 instance 3 exposed
Issued
Apr 5, 2019
Penalty
Initial $632 · Current $379 Reduced
29 CFR 1910.303(e)(1)(ii): Electrical equipment was used when the markings giving voltage, current, wattage, or other ratings as necessary were missing.    In the production area northeast wall, the employer did not ensure electrical panel boxes that energize machinery were marked with voltage ratings.
Recent events (2)
  • — I (O) $379.2
  • — Z (O) $632

View Merrick Engineering's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343893509.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.