OSHA Inspection: APALACHEE POLE COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of APALACHEE POLE COMPANY in 18561 NW CR 12, BRISTOL, FL 32321 (NAICS 321113). OSHA activity number 343893707.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Apalachee Pole Company for free Get an email when a new federal OSHA severe-injury report for Apalachee Pole Company is published. One employer, no account, unsubscribe in one click.
Site address
18561 NW CR 12
City
BRISTOL
State
FL
ZIP
32321
Mailing
P.O. BOX 610, BRISTOL, FL 32321
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
20
Ownership type
Private (A)

3 citations on file for this inspection.

1910.147 C06 I

Other-than-serious 1 instance 6 exposed
Issued
Sep 18, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a. On or about March 27, 2019, the employer had not conducted periodic inspections of their lockout procedures since the year of 2015.
Recent events (1)
  • · Z (O) $0

1910.147 C07 I

Other-than-serious 1 instance 3 exposed
Issued
Sep 18, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:  a. On or about March 21, 2019, the employer did not provide training to authorized and affected employees as to their lockout tagout program.
Recent events (1)
  • · Z (O) $0

1910.1200 F06 II

Other-than-serious 1 instance 1 exposed
Issued
Sep 18, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical:  a. On or about March 21, 2019, a cleaning chemical only identified as NO TOUCH, was found in a secondary container that was not labeled, tagged or marked in accordance with the standard, exposing employees to physical and health hazards of the hazardous chemical.
Recent events (1)
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343893707.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.