Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STRONG FRAMING CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STRONG FRAMING CO. in 2870 DUKE CIR, BOULDER, CO 80305 (NAICS 238130). OSHA activity number 343900502.

Watch Strong Framing CO. — free Get an email when a new federal OSHA severe-injury report for Strong Framing CO. is published. One employer, no account, unsubscribe in one click.
Establishment
STRONG FRAMING CO.
Site address
2870 DUKE CIR
City
BOULDER
State
CO
ZIP
80305
Mailing
5741 ARAPAHOE AVE. STE. 6A, BOULDER, CO 80303
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
2
Ownership type
A

6 citations on file for this inspection.

1926.451 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2842.00 · Current $1400.00 Reduced
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:    (a) Strong Framing Co. at 2870 Duke Cir. Boulder, CO 80303: On or before 4/2/19 the correcting employer did not protect subcontractor employees from injury in that poles supporting a pump jack scaffold did not bear on an approved firm foundation. The ground onsite was soft and muddy and did not adequately support the scaffold poles. This condition exposed subcontractor employees to an unsafe scaffold and fall hazards.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2842

1926.452 J01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(j)(1): 29 CFR 1926.452(j)(1):  Pump jack brackets, braces, and accessories were not fabricated from metal plates and angles. Each pump jack bracket did not have two positive gripping mechanisms to prevent any failure or slippage:  (a) Strong Framing Co. at 2870 Duke Cir. Boulder, CO 80303: On or before 4/2/19 the correcting employer did not protect subcontractor employees from injury in that the pump jack scaffold on the side of the house was secured by a home made wooden bracket. This condition exposed subcontractor employees to an unsafe scaffold and fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F03

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:  (a) Strong Framing Co. at 2870 Duke Cir. Boulder, CO 80303: On or before 4/2/19 the correcting employer did not inspect the pump jack scaffold provided to subcontractor employees to install siding on a new single family home. The scaffold was lacking in structural components and was in use despite those deficiencies. This condition exposed subcontractor employees to an unsafe scaffold and fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F07

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person:  (a) Strong Framing Co. at 2870 Duke Cir. Boulder, CO 80303: On or before 4/2/19 the creating and correcting employer did not ensure the pump jack scaffold provided to subcontractor employees was erected under the supervision of a competent person. The scaffold was erected by subcontractor employees who lacked training in the recognition of hazards. The pump jack scaffold was missing key structural and safety components. These conditions exposed subcontractor employees to an unsafe scaffold and fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  (a) Strong Framing Co. at 2870 Duke Cir. Boulder, CO 80303: On or before 4/2/19 the correcting employer did not protect subcontractor employees from injury in that the pump jack scaffold they were using was not equipped with guard rails or other forms of approved fall protection. The scaffold deck was approximately sixteen feet above grade. This condition exposed subcontractor employees to a fall hazard of approximately sixteen feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1705.00 · Current $900.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     (a) Strong Framing Co. at 2870 Duke Cir. Boulder, CO 80303: On or before 4/2/19 the creating and exposing employer did not protect employees from injury in that an employee working on the roof of a two story single family home was not wearing fall protection. This condition exposed the employee to a fall hazard of approximately ten feet.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1705

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343900502.