Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: GODDARD CONCRETE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GODDARD CONCRETE in 3101 N.E. 10TH STREET, OKLAHOMA CITY, OK 73117 (NAICS 327320). OSHA activity number 343900775.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Goddard Concrete — free Get an email when a new federal OSHA severe-injury report for Goddard Concrete is published. One employer, no account, unsubscribe in one click.
Establishment
GODDARD CONCRETE
Site address
3101 N.E. 10TH STREET
City
OKLAHOMA CITY
State
OK
ZIP
73117
Mailing
3101 N.E. 10TH STREET, OKLAHOMA CITY, OK 73117
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327320
Employees
18
Ownership type
A

5 citations on file for this inspection.

1910.303 F02

Serious Gravity 1 1 instance 1 exposed
Issued
May 2, 2019
Abate by
Jun 17, 2019
Penalty
Initial $1,739 · Current $1,043 Reduced
29 CFR 1910.303(f)(2): Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.  This violation was observed on or about April 2, 2019, on the south outside wall of the maintenance shop, the employer did not ensure circuit panel breakers were correctly labeled as to their purpose exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $1043.4
  • — Z (S) $1739

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
May 2, 2019
Abate by
May 24, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed.  This violation was observed on or about April 2, 2019, on the south outside wall of the maintenance shop, there was an opening in the dead front where the master switch is normally located exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 2 exposed
Issued
May 2, 2019
Abate by
Jun 17, 2019
Penalty
Initial $1,739 · Current $1,043 Reduced
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met.  This violation occurred on or about April 2, 2019, Goddard Concrete did not develop a written hazard communication program for employees required to use hazardous chemicals such as, but not limited to, lubricants, anti-freeze, and grease exposing employees to the effects of hazardous chemicals.
Recent events (2)
  • — I (S) $1043.4
  • — Z (S) $1739

1910.1200 G08

Serious Gravity 1 1 instance 2 exposed
Issued
May 2, 2019
Abate by
Jun 17, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8): The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s).    This violation was observed on or about April 2, 2019, the SDSs for hazardous chemicals such as, but not limited to, lubricants, anti-freeze and grease were not available to employees exposing employees to the hazards of chemical exposure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B02

Other-than-serious 1 instance 2 exposed
Issued
May 2, 2019
Abate by
May 10, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit must be clearly visible and marked by a sign reading "Exit."     This violation was observed on or about April 2, 2019,  the south exit door from the maintenance shop did not have an Exit sign exposing employees to the hazards of delay in exiting the building in case of an emergency.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343900775.