NEW CASTLE, DE ·
OSHA Inspection: YRC INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of YRC INC. in 316 CHURCHMANS ROAD, NEW CASTLE, DE 19720 (NAICS 484110). OSHA activity number 343900965.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- YRC INC.
- Site address
- 316 CHURCHMANS ROAD
- City
- NEW CASTLE
- State
- DE
- ZIP
- 19720
- Mailing
- 316 CHURCHMANS ROAD, NEW CASTLE, DE 19720
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 484110
- Employees
- 30
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.36 E01
- Issued
- Sep 13, 2019
- Penalty
- Initial $10,419 · Current $10,419
General-duty citation text
29 CFR 1910.36(e)(1): A side-hinged door was not used to connected rooms to an exit route: a) Shipping and Receiving Dock - On or about April 12th, 2019, the employer failed to ensure that an emergency exit was installed as a side hinged door when the employer identified and labeled a roll-up type door as an emergency exit.
Recent events (2)
- · I (O) $10419
- · Z (S) $10419
1910.178 A05
- Issued
- Sep 13, 2019
- Abate by
- Oct 9, 2019
- Penalty
- Initial $10,419 · Current $10,419
General-duty citation text
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: a) Shipping and Receiving Dock - On or about August 29th, 2019, the employer failed to ensure that a powered industrial truck had the plates changed to reflect new capacities of the truck when equipped with the available carpet pole, and drum handling attachments.
Recent events (2)
- · I (O) $10419
- · Z (S) $10419
1910.178 A06
- Issued
- Sep 13, 2019
- Abate by
- Oct 9, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates or markings were maintained in a legible condition: (a) Shipping and Receiving Dock - On or about August 29th, 2019, the employer failed to ensure that all plates were maintained in a legible condition.
Recent events (2)
- · I (O) $0
- · Z (S) $0
1910.178 Q07
- Issued
- Sep 13, 2019
- Abate by
- Oct 9, 2019
- Penalty
- Initial $12,503 · Current $13,260
General-duty citation text
29 CFR 1910.178(q)(7): Powered industrial truck(s) which were used on a round-the-clock basis were not examined for defects after each shift: (a) Loading Dock Area - On or about April 12th, 2019, the employer failed to ensure that examinations were performed on powered industrial trucks used on both day and night shifts.
Recent events (2)
- · I (O) $13260
- · Z (S) $12503
1910.303 B02
- Issued
- Sep 13, 2019
- Abate by
- Oct 9, 2019
- Penalty
- Initial $12,503 · Current $12,503
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Maintenance Shop - On or about April 12th, 2019, the employer failed to install a light switch, instead requiring employees to turn the lights on using a standard 15 amp Circuit Breaker, which was not listed or labeled as a 15 amp Switch Duty (SWD) Circuit Breaker.
Recent events (2)
- · I (O) $12503
- · Z (S) $12503
More inspections at YRC INC.
View YRC INC.'s full OSHA safety record →
More inspections in this industry (NAICS 484110)
More inspections in DE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343900965.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.