Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PEDRO RODRIGUEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PEDRO RODRIGUEZ in 1364 LEESLAND DRIVE, WESTERVILLE, OH 43081 (NAICS 238140). OSHA activity number 343904025.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pedro Rodriguez — free Get an email when a new federal OSHA severe-injury report for Pedro Rodriguez is published. One employer, no account, unsubscribe in one click.
Establishment
PEDRO RODRIGUEZ
Site address
1364 LEESLAND DRIVE
City
WESTERVILLE
State
OH
ZIP
43081
Mailing
180 DEMOREST ROAD, COLUMBUS, OH 43204
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
2
Ownership type
A

5 citations on file for this inspection.

1926.451 B01 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Apr 16, 2019
Abate by
Apr 26, 2019
Penalty
Initial $2,415 · Current $0 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:  29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).   a. On or about April 3, 2019, located at 1364 Leesland Drive in Westerville, Ohio, the first buck of scaffolding was not fully planked for employees to access side brackets, thereby exposing the employees to a fall hazard of approximately 6-7 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2415

1926.451 C03

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Apr 16, 2019
Abate by
Apr 26, 2019
Penalty
Initial $2,415 · Current $0 Reduced
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, posts, frames, and uprights shall be plumb and braced to prevent swaying and displacement.  a. On or about April 3, 2019, located at 1364 Leesland Drive in Westerville, Ohio, employees worked from a fabricated framed scaffold that was not plumb exposing the employees to a falls and/or struck-by/caught-between hazards if a scaffold collapse occurred.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2415

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 16, 2019
Abate by
Apr 26, 2019
Penalty
Initial $1,932 · Current $1,932
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.   a. On or about April 3, 2019, located at 1364 Leesland Drive in Westerville, Ohio, employees were working from a fabricated frame scaffold without a safe means to access side brackets, thereby exposing the employees to a maximum fall hazard of 6-7 feet.
Recent events (2)
  • — I (S) $1932
  • — Z (S) $1932

1926.451 H02 II

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Apr 16, 2019
Abate by
Apr 26, 2019
Penalty
Initial $1,932 · Current $0 Reduced
29 CFR 1926.451(h)(2)(ii): A toeboard shall be erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below, except on float (ship) scaffolds where an edging of 3/4 x 1 1/2 inch (2 x 4 cm) wood or equivalent may be used in lieu of toeboards;  a. On or about April 3, 2019, located at 1364 Leesland Drive in Westerville, Ohio, employees worked from a fabricated frame scaffold that did not have toeboards erected along the edge of all platforms, thereby exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1932

1926.452 C05 III

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 16, 2019
Abate by
Apr 26, 2019
Penalty
Initial $2,415 · Current $2,415
29 CFR 1926.452(c)(5)(iii): Be used only to support personnel, unless the scaffold has been designed for other loads by a qualified engineer and built to withstand the tipping forces caused by those other loads being placed on the bracket-supported section of the scaffold.   a. On or about April 3, 2019, located at 1364 Leesland Drive in Westerville, Ohio, employees worked from a fabricated frame scaffold that had side brackets installed onto the outside of the scaffolding with a bundle of bricks and a mortar bucket putting the scaffolding at risk of collapse, thereby exposing the employees to fall and/or struck-by/caught-between hazards.
Recent events (2)
  • — I (S) $2415
  • — Z (S) $2415

View Pedro Rodriguez's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343904025.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.