Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: SMITH'S AUTO BODY SHOP INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of SMITH'S AUTO BODY SHOP INC. in 6906 EAST WASHINGTON STREET EXT., BATH, NY 14810 (NAICS 811121). OSHA activity number 343908141.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Smith'S Auto Body Shop INC. for free Get an email when a new federal OSHA severe-injury report for Smith'S Auto Body Shop INC. is published. One employer, no account, unsubscribe in one click.
Site address
6906 EAST WASHINGTON STREET EXT.
City
BATH
State
NY
ZIP
14810
Mailing
6906 EAST WASHINGTON STREET EXT., BATH, NY 14810
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
7
Ownership type
Private (A)

5 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 18, 2019
Abate by
May 23, 2019
Penalty
Initial $1,705 · Current $1,705
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:   a) Throughout the facility, On or about 4/4/19: A written respirator program was not implemented for employees required to wear half mask air purifying respirators while working with chemicals including, but not limited to, total and respirable particulate; and PPG paint products such as  DC 3000 containing xylene, MC262 containing acetone,  and NCP271 containing talc.     Abatement certification must be submitted for this item.
Recent events (1)
  • · Z (S) $1705

1910.134 D01 III

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 18, 2019
Abate by
May 23, 2019
Penalty
Initial $0 · Current $0

Hazardous substances 259091309135

29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:   a) Throughout the facility, On or about 4/4/19: An estimate of exposure was not performed for body shop employees required to wear half mask air purifying respirators and that work with chemicals including, but not limited to, total and respirable particulate; and PPG paint products such as  DC 3000 containing xylene, MC262 containing acetone,  and NCP271 containing talc.     Abatement certification must be submitted for this item.
Recent events (1)
  • · Z (S) $0

1910.134 E01

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 18, 2019
Abate by
May 23, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace    a) Throughout the facility, On or about 4/4/19: Medical evaluations were not provided for employees required to wear half mask air purifying respirators while working with chemicals including, but not limited to, total and respirable particulate; and PPG paint products such as  DC 3000 containing xylene, MC262 containing acetone,  and NCP271 containing talc.     Abatement certification must be submitted for this item.
Recent events (1)
  • · Z (S) $0

1910.134 K03

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 18, 2019
Abate by
May 23, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace  a) Throughout the facility, On or about 4/4/19: Training was not provided for employees required to wear half mask air purifying respirators while working with chemicals including, but not limited to, total and respirable particulate; and PPG paint products such as  DC 3000 containing xylene, MC262 containing acetone,  and NCP271 containing talc.     Abatement certification must be submitted for this item.
Recent events (1)
  • · Z (S) $0

1910.1200 E01

Other-than-serious 1 instance 5 exposed
Issued
Apr 18, 2019
Abate by
May 23, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):   a) Throughout the facility, on or about 4/4/19: A hazard communication program was not developed in written form for employees working with chemicals including, but not limited to,  refrigerants such as  R1234YF and  PPG paint products such as  DC 3000 containing xylene, MC262 containing acetone,  and NCP271 containing talc.     Abatement certification must be submitted for this item
Recent events (1)
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343908141.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.