MIAMI, FL ·
OSHA Inspection: DEDIENNE AEROSPACE LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of DEDIENNE AEROSPACE LLC in 2500 NW 74TH AVE, MIAMI, FL 33122 (NAICS 333923). OSHA activity number 343915260.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DEDIENNE AEROSPACE LLC
- Site address
- 2500 NW 74TH AVE
- City
- MIAMI
- State
- FL
- ZIP
- 33122
- Mailing
- 2500 NW 74TH AVE, MIAMI, FL 33122
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333923
- Employees
- 51
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.134 E01
- Issued
- Jul 31, 2019
- Abate by
- Aug 19, 2019
- Penalty
- Initial $0 · Current $0
W103
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace. On or about April 8, 2019, at the carpentry area located at 2500 NW 74th Avenue, Miami, Florida 33122, the employer did not provide medical evaluations for employees who are required to wear GVS tight-fitting facepiece respirators while performing cutting, fabricating pallets and crates.
Recent events (1)
- · Z (O) $0
1910.134 F01
- Issued
- Jul 31, 2019
- Abate by
- Aug 19, 2019
- Penalty
- Initial $0 · Current $0
W103
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): On or about April 8, 2019, at the carpentry area located at 2500 NW 74th Avenue, Miami, Florida 33122, the employer did not ensure employees who were required to wear GVS tight-fitting facepiece respirators while performing cutting, fabricating pallets and crates had passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT).
Recent events (1)
- · Z (O) $0
1910.134 G01 I A
- Issued
- Jul 31, 2019
- Abate by
- Aug 19, 2019
- Penalty
- Initial $0 · Current $0
W103
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: On or about April 8, 2019, at the carpentry area located at 2500 NW 74th Avenue, Miami, Florida 33122, employees who were required to wear GVS tight-fitting half face respirators while performing cutting, fabricating pallets and crates were not prohibited from growing facial hair.
Recent events (1)
- · Z (O) $0
More inspections in this industry (NAICS 333923)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343915260.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.