PLEASANT PRAIRIE, WI ·
OSHA Inspection: KEYSTONE EXTERIORS FINISHES, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KEYSTONE EXTERIORS FINISHES, LLC in 10551 120TH AVE., PLEASANT PRAIRIE, WI 53158 (NAICS 238990). OSHA activity number 343918181.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KEYSTONE EXTERIORS FINISHES, LLC
- Site address
- 10551 120TH AVE.
- City
- PLEASANT PRAIRIE
- State
- WI
- ZIP
- 53158
- Mailing
- 616 GRAND AVE., MUKWONAGO, WI 53149
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 2
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.100 A
- Issued
- May 10, 2019
- Abate by
- May 16, 2019
- Penalty
- Initial $1,705 · Current $0 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) The employer did not ensure employees were using head protection when working under equipment, material, and personnel. At the worksite located at 10551 120th Ave., Pleasant Prairie, WI, an employee was working under the boom of an aerial lift, thereby being exposed to struck-by hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $1705
1926.453 B02 V
- Issued
- May 10, 2019
- Abate by
- May 16, 2019
- Penalty
- Initial $3,410 · Current $0 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift:Note: As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated: (a) The employer did not ensure employees were using fall protection when conducting work from an aerial lift. At the worksite located at 10551 120th Ave., Pleasant Prairie, WI, an employee did not fully utilize fall protection systems in an aerial lift, thereby being exposed to a fall hazard.
Recent events (2)
- · I (S) $0
- · Z (S) $3410
1926.21 B02
- Issued
- May 10, 2019
- Abate by
- Jun 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: (a) The employer did not ensure employees were trained in recognizing fall hazards and implementing fall protection when conducting work from an platform of an aerial lift. On or about 4-9-19, a foreman employee was performing work from an elevated platform located in the drive thru area of a McDonald's restaurant and was not using fall protection.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 238990)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343918181.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.