OSHA Inspection: CONTRACT FUSION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CONTRACT FUSION, INC. in 99 MASSASOIT AVENUE, EAST PROVIDENCE, RI 02914 (NAICS 332710). OSHA activity number 343919817.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Contract Fusion, INC. for free Get an email when a new federal OSHA severe-injury report for Contract Fusion, INC. is published. One employer, no account, unsubscribe in one click.
Site address
99 MASSASOIT AVENUE
City
EAST PROVIDENCE
State
RI
ZIP
02914
Mailing
99 MASSASOIT AVENUE, EAST PROVIDENCE, RI 02914
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
25
Ownership type
Private (A)

8 citations on file for this inspection.

1910.132 D01

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 24, 2019
Abate by
Jun 10, 2019
Penalty
Initial $3,031 · Current $1,515 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):     (a) Worksite:  On or about 4/10/2019, the employer did not ensure that a hazard assessment for personal protective equipment (PPE) was completed and certified, and that the necessary PPE was selected and provided to employees for their protection.
Recent events (2)
  • · I (S) $1515
  • · Z (S) $3031

1910.147 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 24, 2019
Abate by
Jun 10, 2019
Penalty
Initial $3,789 · Current $1,895 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:     (a) Worksite:  On or about 4/10/2019, the employer had not developed a Lockout/Tag-out program to address the control of machine energy sources during repairs and maintenance.
Recent events (2)
  • · I (S) $1895
  • · Z (S) $3789

1910.212 A01

Serious Gravity 5 6 instances 2 exposed
Issued
Apr 24, 2019
Abate by
Jun 10, 2019
Penalty
Initial $3,789 · Current $1,895 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) Worksite:  On or about 4/10/2019, the employer did not ensure that machine guarding was provided on the following machines: Vertical Milling Machines, Lathe, Belt Sander and Buffing Wheel Spindle Ends.
Recent events (2)
  • · I (S) $1895
  • · Z (S) $3789

1910.212 B

Serious Gravity 5 3 instances 2 exposed
Issued
Apr 24, 2019
Abate by
Jun 10, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Machines designed for fixed locations were not securely anchored to prevent walking or moving:   (a) Worksite:  On or about 4/10/2019, the employer did not ensure that floor and bench mounted pedestal drill presses were secured from movement.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 24, 2019
Abate by
Jun 10, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:   (a) Worksite:  On or about 4/10/2019, the employer did not ensure that the bench grinder was equipped with adjustable tongue guards that were adjusted to within one-fourth inch from the abrasive wheel.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.219 E01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 24, 2019
Abate by
Jun 10, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:   (a) Worksite - Tool Room:  On or about 4/10/2019, the employer did not ensure that the horizontal belts on the Rockwell drill press were properly guarded, and that the Delta and Langelier drill press horizontal belts were fully guarded.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.255 B04

Deleted Serious Gravity 5 50 instances 2 exposed
Issued
Apr 24, 2019
Abate by
Jun 10, 2019
Penalty
Initial $4,546 · Current $0 Reduced
29 CFR 1910.255(b)(4): All press welding machine operations, where there is a possibility of the operator's fingers being under the point of operation, were not effectively guarded by the use of a device such as an electronic eye safety circuit, two hand controls or protection similar to that prescribed for punch press operation:  (a) Worksite:  On or about 4/10/2019, the employer did not ensure that the electronic welding units were properly guarded to prevent the operator's fingers and hands from being in the welding point of operation when the units were engaged.
Recent events (2)
  • · I (S) $0
  • · Z (S) $4546

1910.255 B06

Deleted Serious Gravity 5 50 instances 2 exposed
Issued
Apr 24, 2019
Abate by
Jun 10, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.255(b)(6): All foot switches were not guarded to prevent accidental operation of the machine:   (a) Worksite:  On or about 4/10/2019, the employer did not ensure that the foot pedals that actuate the electronic welding units were guarded to prevent the operator, or anyone else, from accidentally engaging the machine while the operators hands or fingers were in the welding point of operation.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Contract Fusion, INC.'s full OSHA safety record →