FINDLAY, OH ·
OSHA Inspection: VEONEER NISSIN BRAKE SYSTEMS OF AMERICA, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of VEONEER NISSIN BRAKE SYSTEMS OF AMERICA, INC. in 1901 INDUSTRIAL AVE., FINDLAY, OH 45840 (NAICS 336340). OSHA activity number 343920013.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VEONEER NISSIN BRAKE SYSTEMS OF AMERICA, INC.
- Site address
- 1901 INDUSTRIAL AVE.
- City
- FINDLAY
- State
- OH
- ZIP
- 45840
- Mailing
- 1901 INDUSTRIAL AVE., FINDLAY, OH 45840
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336340
- Employees
- 125
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.147 C07 I
- Issued
- Aug 28, 2019
- Abate by
- Sep 16, 2019
- Penalty
- Initial $11,366 · Current $6,820 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a.) On or about April 4, 2019, the employer did not ensure that employees were adequately trained in the lockout procedures for the Master Power Line #1 Index Station. Employees did not lock out and tag out the electrical panel while performing unjamming activities on equipment including, but not limited to the Index Station.
Recent events (2)
- · I (S) $6820
- · Z (S) $11366
1910.147 D
- Issued
- Aug 28, 2019
- Abate by
- Sep 16, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a.) On or about April 4, 2019, employees were exposed to amputation injuries in that the Master Power Line #1 Index Station was not locked out prior performing change over activities, including but not limited to unjamming the diaphragm and bladder. The employer did not ensure that energy control application steps to control the electrical energy sources were implemented prior to maintenance tasks the employer did not: � Physically operate energy isolating devices to control energy sources and affix lockout device(s). � Ensure that all potentially hazardous stored or residual energy was relieved, disconnected, and rendered safe. � Verify that isolation and deenergization of the machine or equipment had been accomplished.