Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: VEONEER NISSIN BRAKE SYSTEMS OF AMERICA, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of VEONEER NISSIN BRAKE SYSTEMS OF AMERICA, INC. in 1901 INDUSTRIAL AVE., FINDLAY, OH 45840 (NAICS 336340). OSHA activity number 343920013.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Veoneer Nissin Brake Systems of America, INC. for free Get an email when a new federal OSHA severe-injury report for Veoneer Nissin Brake Systems of America, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1901 INDUSTRIAL AVE.
City
FINDLAY
State
OH
ZIP
45840
Mailing
1901 INDUSTRIAL AVE., FINDLAY, OH 45840
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336340
Employees
125
Ownership type
Private (A)

2 citations on file for this inspection.

1910.147 C07 I

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 28, 2019
Abate by
Sep 16, 2019
Penalty
Initial $11,366 · Current $6,820 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:     a.)     On or about April 4, 2019, the employer did not ensure that employees were adequately trained in the lockout procedures for the Master Power Line #1 Index Station.  Employees did not lock out and tag out the electrical panel while performing unjamming activities on equipment including, but not limited to the Index Station.
Recent events (2)
  • · I (S) $6820
  • · Z (S) $11366

1910.147 D

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 28, 2019
Abate by
Sep 16, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):   a.)     On or about April 4, 2019, employees were exposed to amputation injuries in that the Master Power Line #1 Index Station was not locked out prior performing change over activities, including but not limited to unjamming the diaphragm and bladder. The employer did not ensure that energy control application steps to control the electrical energy sources were implemented prior to maintenance tasks  the employer did not:  �  Physically operate energy isolating devices to control energy sources and affix lockout device(s).  �  Ensure that all potentially hazardous stored or residual energy was relieved, disconnected, and rendered safe.  �  Verify that isolation and deenergization of the machine or equipment had been accomplished.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343920013.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.