AUSTINTOWN, OH ·
OSHA Inspection: NORDSON XALOY INCORPORATED
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NORDSON XALOY INCORPORATED in 375 VICTORIA ROAD, AUSTINTOWN, OH 44515 (NAICS 333999). OSHA activity number 343921870.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NORDSON XALOY INCORPORATED
- Site address
- 375 VICTORIA ROAD
- City
- AUSTINTOWN
- State
- OH
- ZIP
- 44515
- Mailing
- 375 VICTORIA ROAD, AUSTINTOWN, OH 44515
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333999
- Employees
- 315
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.147 C06 I
- Issued
- May 30, 2019
- Abate by
- Jun 19, 2019
- Penalty
- Initial $7,577 · Current $7,577
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about April 10, 2019, the employer failed to ensure periodic inspections of their lockout/tagout procedures were conducted within the past 12 months.
Recent events (1)
- · Z (S) $7577
1910.303 B02
- Issued
- May 30, 2019
- Penalty
- Initial $5,683 · Current $5,683
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about April 10, 2019, the Owatonna 10,000psi electric powered hydraulic jack at asset W-0127 straightener was plugged into a commercial grade electrical multi-tap switch that was laying on the work floor.
Recent events (1)
- · Z (S) $5683
1910.212 A01
- Issued
- May 30, 2019
- Penalty
- Initial $47,360 · Current $47,360
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about April 10, 2019, the employer failed to ensure that the Kingston lathe (W0221), which was being used in the group 3 area, was effectively guarded. The horizontal lathe did not have a chuck guard in place. NORDSON XALOY INCORPORATED WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVELENT STANDARD 29 CFR 1910.212(a)(1) WHICH WAS CONTAINED IN OSHA INSPECTION 1363167, CITATION 1, ITEM 1 AND WAS AFFIRMED AS A FINAL ORDER ON JANUARY 7, 2019, WITH RESPECT TO A WORKPLACE LOCATED AT 375 VICTORIA ROAD AUSTINTOWN, OHIO 44515.
Recent events (1)
- · Z (R) $47360
More inspections at Nordson Xaloy Incorporated
View Nordson Xaloy Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 333999)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343921870.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.