OSHA Inspection: R&R MILLWORK, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of R&R MILLWORK, INC. in 1500 W DARTMOUTH AVE, ENGLEWOOD, CO 80110 (NAICS 337212). OSHA activity number 343923843.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R&R Millwork, INC. — free Get an email when a new federal OSHA severe-injury report for R&R Millwork, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
R&R MILLWORK, INC.
Site address
1500 W DARTMOUTH AVE
City
ENGLEWOOD
State
CO
ZIP
80110
Mailing
1500 W DARTMOUTH AVE, ENGLEWOOD, CO 80110
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337212
Employees
38
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 1 1 instance 4 exposed
Issued
May 2, 2019
Abate by
Jun 19, 2019
Penalty
Initial $3,978 · Current $2,300 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.    a) On or about April 11, 2019, and at times prior, workers were exposed to hazardous energy where specific procedures did not include the steps to isolate and lock out air pressure to shop machines including, but not limited to the CNC Panel Saws.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $2300
  • — Z (S) $3978

1910.147 C04 II C

Serious Gravity 1 1 instance 4 exposed
Issued
May 2, 2019
Abate by
Jun 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them:  a) On or about April 11, 2019, and at times prior, workers were exposed to hazardous energy where equipment-specific lockout procedures did not include the steps to transfer locks among workers such as but not limited to other shifts, prolonged absences, etc.  Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 II D

Serious Gravity 1 1 instance 4 exposed
Issued
May 2, 2019
Abate by
Jun 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures:  a) On or about April 11, 2019, and at times prior, workers were exposed to hazardous energy where equipment-specific lockout procedures did not include the steps to ensure hazardous air pressure was bled from the system prior to starting a maintenance task.  Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I A

Serious Gravity 1 1 instance 4 exposed
Issued
May 2, 2019
Abate by
Jun 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Authorized employees did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:  a) On or about April 11, 2019, and at times prior, workers were exposed to hazards in that the lockout program, procedures, and training material did not indicate the electrical power and air pressure present in the workplace or alternatively, at each separate machine covered by a lockout procedure.  Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0