Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TEKTON CONSTRUCTION, LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of TEKTON CONSTRUCTION, LLC in 844 MCCARTHY ROAD, ERIEVILLE, NY 13061 (NAICS 238990). OSHA activity number 343923868.

Watch Tekton Construction, LLC — free Get an email when a new federal OSHA severe-injury report for Tekton Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
844 MCCARTHY ROAD
City
ERIEVILLE
State
NY
ZIP
13061
Mailing
1756 YAGER ROAD, DURHAMVILLE, NY 13054
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
13
Ownership type
A

8 citations on file for this inspection.

1926.304 H01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3031.00 · Current $0.00 Reduced
29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut:Note:  See paragraph (i)(1) of this section for additional requirements for hand-fed crosscut table saws.  a) At the jobsite, on or about 4/3/19:  Workers were using a DeWalt table saw to cut trim wood and siding for interior and exterior installation and without a guard.
Recent events (3)
  • — J (S) $0
  • — C (S) $3031
  • — Z (S) $3031

1926.304 F

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.304(f): Section 5.1.3.3 American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  Electrically driven equipment was not controlled with magnetic switches or other devices that would prevent automatic restarting of the machine after a power failure  a) At the jobsite, on or about 4/3/19:  Workers were using a DeWalt table saw to cut trim wood and siding for interior and exterior installation and without a guard and where that saw did not have an anti-restart function.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.404 B01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3031.00 · Current $0.00 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction site:  a) At the jobsite, on or about 4/3/19:  Workers were using power tools that were energized through temporary connections through the service panel and without GFI protection.
Recent events (3)
  • — J (S) $0
  • — C (S) $3031
  • — Z (S) $3031

1926.405 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed:  a) At the jobsite, on or about 4/3/19:  Workers were using power tools that were energized through temporary connections through the service panel where two breaker positions were open.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $5304.00 · Current $2200.00 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used:  a) At the jobsite, on or about 4/3/19:  Employees were working from a ladder jack scaffold that was 10 feet from ground on one end and 16 feet from ground on the opposite end, and where they accessed the pick by climbing onto it, without a ladder to access the work surface.
Recent events (3)
  • — J (S) $2200
  • — C (S) $5304
  • — Z (S) $5304

1926.451 G01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.  a) At the jobsite, on or about 4/3/19:  Employees were working from a ladder jack scaffold that was 10 feet from ground on one end and 16 feet from ground on the opposite end, and without fall protection of any kind.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3031.00 · Current $0.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) At the jobsite, on or about 4/3/19:  Workers used a Werner 10 foot step ladder inside an unfinished interior stairwell to access the second floor from the basement level, where that ladder was leaned against the floor end, did not extend at least 3 feet above the landing being accessed, and was not opened and spreaders locked out as it is designed to be used.
Recent events (3)
  • — J (S) $0
  • — C (S) $3031
  • — Z (S) $3031

1926.1053 B04

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  a) At the jobsite, on or about 4/3/19:  Workers used a Werner 10 foot step ladder inside an unfinished interior stairwell to access the second floor from the basement level, where that ladder was leaned against the floor end and was not opened and spreaders locked out as it is designed to be used.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343923868.