Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BELFOR PROPERTY RESTORATION

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of BELFOR PROPERTY RESTORATION in 255 GRAND UNION BLVD, SOMERVILLE, MA 02145 (NAICS 238990). OSHA activity number 343930954.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Belfor Property Restoration — free Get an email when a new federal OSHA severe-injury report for Belfor Property Restoration is published. One employer, no account, unsubscribe in one click.
Site address
255 GRAND UNION BLVD
City
SOMERVILLE
State
MA
ZIP
02145
Mailing
138 BARTLETT ST., MARLBOROUGH, MA 01752
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
1000
Ownership type
A

4 citations on file for this inspection.

1910.134 D01 I

Serious Gravity 10 1 instance 8 exposed
Issued
Jun 27, 2019
Abate by
Dec 31, 2019
Penalty
Initial $13,260 · Current $6,000 Reduced

Hazardous substances C730

29 CFR 1910.134(d)(1)(i): Selection of appropriate respirators was not based on the respiratory hazard(s) to which the worker was exposed and user factors that affect respirator performance and reliability:    Location - 255 Grand Union Blvd., Somerville, MA, 02145    On April 11, 2019, employer did not provide appropriate respiratory protection equipment, while employees were working under carbon monoxide exposure.
Recent events (3)
  • — F (S) $6000
  • — C (S) $13260
  • — Z (S) $13260

1910.1000 A02

Serious Gravity 10 1 instance 8 exposed
Issued
Jun 27, 2019
Penalty
Initial $13,260 · Current $0 Reduced

Hazardous substances C730

29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:  Location - 255 Grand Union Blvd., Somerville, MA, 02145  On or about April,11 2019, the employer had not performed an evaluation or identification of respiratory hazard for chemical hazard, such as, but not limited to, carbon monoxide, while operating powered washer machine in an enclosed area.   (a) An employee was exposed to carbon monoxide (CO), during cleaning of fire residues. The level of the carbon monoxide (CO) was at an 8-hour time weighted average (TWA) of 114.7 ppm as determined by the employee's Carboxyhemoglobin (%COHb), which was 2.29 times the permissible exposure limit of 50 ppm CO.    (b) An employee was exposed to carbon monoxide (CO), during cleaning of fire residues. The level of the carbon monoxide (CO) was at an 8-hour time weighted average (TWA) of 85.2 ppm as determined by the employee's Carboxyhemoglobin (%COHb), which was 1.70 times the permissible exposure limit of 50 ppm CO.     29 CFR 1910.1000(a)(2): Other substances -- 8-hour Time Weighted Averages. An employee's exposure to any substance in Table Z-1, the exposure limit of which is not preceded by a "C", shall not exceed the 8-hour Time Weighted Average given for that substance any 8-hour work shift of a 40-hour work week.    Location - 255 Grand Union Blvd., Somerville, MA, 02145    (a) On or about April 11, 2019, an employee was exposed to carbon monoxide (CO), during cleaning of fire residues. The level of the carbon monoxide (CO) was at an 8-hour time weighted average (TWA) of 114.7 ppm as determined by the employee's Carboxyhemoglobin (%COHb), which was 2.29 times the permissible exposure limit of 50 ppm CO.        (b) On or about April 11, 2019, an employee was exposed to carbon monoxide (CO), during cleaning of fire residues. The level of the carbon monoxide (CO) was at an 8-hour time weighted average (TWA) of 85.2 ppm as determined by the employee's Carboxyhemoglobin (%COHb), which was 1.70 times the permissible exposure limit of 50 ppm CO.
Recent events (3)
  • — F (S) $0
  • — C (S) $13260
  • — Z (S) $13260

1910.1000 E

Serious Gravity 10 1 instance 8 exposed
Issued
Jun 27, 2019
Penalty
Initial $0 · Current $0

Hazardous substances C730

29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):    Location - 255 Grand Union Blvd., Somerville, MA, 02145    On or about April 11, 2019, the employer did not implement an effective combination of engineering and work practice controls to reduce and maintain employee(s) exposures to carbon monoxide to or below 50 parts per million or less.     (a) An employee was exposed to carbon monoxide (CO), during cleaning of fire residues. The level of the carbon monoxide (CO) was at an 8-hour time weighted average (TWA) of 114.7 ppm as determined by the employee's Carboxyhemoglobin (%COHb), which was 2.29 times the permissible exposure limit of 50 ppm CO.        (b) An employee was exposed to carbon monoxide (CO), during cleaning of fire residues. The level of the carbon monoxide (CO) was at an 8-hour time weighted average (TWA) of 85.2 ppm as determined by the employee's Carboxyhemoglobin (%COHb), which was 1.70 times the permissible exposure limit of 50 ppm CO.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 F02

Deleted Serious Gravity 1 1 instance 8 exposed
Issued
Jun 27, 2019
Abate by
Jul 31, 2019
Penalty
Initial $5,683 · Current $0 Reduced
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:  Location - 255 Grand Union Blvd., Somerville, MA, 02145  On or about April 11, 2019, On or about April 11, 2019, employer allowed employee required to wear tight fitting respirator to not undergo proper annual fit testing.
Recent events (3)
  • — F (S) $0
  • — C (S) $5683
  • — Z (S) $5683

View Belfor Property Restoration's full OSHA safety record →