CYPRESS, TX —
OSHA Inspection: CARLO LOPEZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CARLO LOPEZ in 18803 ONION CREEK CT, CYPRESS, TX 77433 (NAICS 238130). OSHA activity number 343931846.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CARLO LOPEZ
- Site address
- 18803 ONION CREEK CT
- City
- CYPRESS
- State
- TX
- ZIP
- 77433
- Mailing
- 10615 BEECHNUT ST. APT 316, HOUSTON, TX 77072
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 C02
- Issued
- Apr 30, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation. On or about April 12, 2019 at a residential construction job site where employees were exposed to a fall hazard when working from an elevated pump jack scaffold without base plates and mud sills or other adequate firm foundation.
Recent events (1)
- — Z (S) $2842
1926.451 G01 VII
- Issued
- Apr 30, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. On or about April 12, 2019 at the job site where employees were exposed to a fall hazard when working on an elevated pump jack scaffold more than 10 feet above the ground without being protected from falls by the use of personal fall arrest systems or guardrail systems.
Recent events (1)
- — Z (S) $2842
1926.452 J02
- Issued
- Apr 30, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. On or about April 12, 2019 at a residential construction job site where employees were exposed to a fall hazard when working on an elevated pump jack scaffold without the scaffold being secured at the bottom by a rigid triangular brace.
Recent events (1)
- — Z (S) $2842
More inspections at Carlo Lopez
View Carlo Lopez's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343931846.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.