FULSHEAR, TX ·
OSHA Inspection: PADDOCK SOUTHWEST, LLC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of PADDOCK SOUTHWEST, LLC in 27500 FULSHEAR BEND, FULSHEAR, TX 77441 (NAICS 238990). OSHA activity number 343936084.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PADDOCK SOUTHWEST, LLC
- Site address
- 27500 FULSHEAR BEND
- City
- FULSHEAR
- State
- TX
- ZIP
- 77441
- Mailing
- 1305 W THOMAS AVE, PASADENA, TX 77506
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 21
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.651 C02
- Issued
- Jun 10, 2019
- Abate by
- Jun 20, 2019
- Penalty
- Initial $5,636 · Current $3,382 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) In the Natatorium area, where the excavated pool was not equipped with a means of egress every 25 feet.
Recent events (2)
- · I (S) $3381.6
- · Z (S) $5636
1926.651 K01
- Issued
- Jun 10, 2019
- Abate by
- Jun 20, 2019
- Penalty
- Initial $5,636 · Current $3,382 Reduced
General-duty citation text
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift: a) In the Natatorium area, where there was no competent person to inspect the excavated pool prior to employees starting work for the day.
Recent events (2)
- · I (S) $3381.6
- · Z (S) $5636
1926.652 A01
- Issued
- Jun 10, 2019
- Abate by
- Jun 20, 2019
- Penalty
- Initial $5,636 · Current $3,382 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c): a) In the Natatorium area, where the excavated pool soil was not protected from cave-ins by an adequate protective system.
Recent events (2)
- · I (S) $3381.6
- · Z (S) $5636
More inspections in this industry (NAICS 238990)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343936084.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.