PECOS, TX ·
OSHA Inspection: FLUID & EQUIPMENT TRANSPORTATION INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FLUID & EQUIPMENT TRANSPORTATION INC. in 33 W. COUNTY RD. HWY 424, PECOS, TX 79772 (NAICS 213112). OSHA activity number 343937843.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLUID & EQUIPMENT TRANSPORTATION INC.
- Site address
- 33 W. COUNTY RD. HWY 424
- City
- PECOS
- State
- TX
- ZIP
- 79772
- Mailing
- 1 TYLER COUNT, CARLISLE, PA 17015
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 125
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.22 A01
- Issued
- Jul 12, 2019
- Abate by
- Jul 24, 2019
- Penalty
- Initial $5,115 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): (1) All places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition. On or about April 16, 2019, outside and inside the mechanic shop area, passageways and walking-working surfaces were not kept in a clean, orderly, and sanitary condition. This condition exposed employees to trip and fall hazards.
Recent events (2)
- · I (S) $2500
- · Z (S) $5115
1910.305 B02 I
- Issued
- Jul 12, 2019
- Abate by
- Jul 18, 2019
- Penalty
- Initial $10,229 · Current $7,500 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: On or about April 16, 2019, located in the mechanic shop, the electrical box housing 120V live conductors did not have a cover on its front and no fitting where the wire entered on top of the box. This condition exposed employees to electrical shock hazards.
Recent events (2)
- · I (S) $7500
- · Z (S) $10229
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343937843.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.