Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KDC ONE NORTHERN LABS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of KDC ONE NORTHERN LABS in 5800 WEST DRIVE, MANITOWOC, WI 54220 (NAICS 325612). OSHA activity number 343937884.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch KDC ONE Northern Labs — free Get an email when a new federal OSHA severe-injury report for KDC ONE Northern Labs is published. One employer, no account, unsubscribe in one click.
Site address
5800 WEST DRIVE
City
MANITOWOC
State
WI
ZIP
54220
Mailing
PO BOX 850, MANITOWOC, WI 54220
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325612
Employees
300
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 26, 2019
Abate by
Dec 31, 2019
Penalty
Initial $13,260 · Current $13,260
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.     On or about April 9, 2019, KDC One Northern Lab's specific procedure for the Capper on Line #3 did not account for the pneumatic energy source of the machine.      Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance.
Recent events (2)
  • — I (S) $13260
  • — Z (S) $13260

1910.147 C06 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 26, 2019
Abate by
Dec 31, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.    On or about April 9, 2019, KDC One Northern Labs had not conducted a periodic inspection of their energy control procedures within the last twelve months.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 26, 2019
Penalty
Initial $13,260 · Current $0 Reduced
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence as required by 29 CFR 1910.147(d)(1)-(6):    On or about April 9, 2019, an employee was exposed to machine hazards associated with in-going nip points when they engaged in servicing and maintenance activities on the Capper Machine on Line #3. The employer did not ensure that energy control application steps to control the electrical and pneumatic energy sources were implemented prior to allowing employees to adjust torque for the Capper wheels. The machine was not shut down or turned off prior to engaging in this service and maintenance activity.    As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine servicing hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13260

View KDC ONE Northern Labs's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343937884.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.