OSHA Inspection: AGMOTION, INC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of AGMOTION, INC in 1 RAILROAD AVE, SUNBURST, MT 59482 (NAICS 493130). OSHA activity number 343938197.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Agmotion, INC — free Get an email when a new federal OSHA severe-injury report for Agmotion, INC is published. One employer, no account, unsubscribe in one click.
Establishment
AGMOTION, INC
Site address
1 RAILROAD AVE
City
SUNBURST
State
MT
ZIP
59482
Mailing
730 SECOND AVE S, STE 700, MINNEAPOLIS, MN 55402
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493130
Employees
80
Ownership type
A

5 citations on file for this inspection.

1910.219 D01

Serious Gravity 5 2 instances 3 exposed
Issued
Jul 29, 2019
Abate by
Aug 22, 2019
Penalty
Initial $5,304 · Current $2,652 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    a) Area near Truck Pit electrical disconnect switch: On or about April 16, 2019 and at times prior, employees were exposed to caught-in hazards while walking and working around the unguarded pulley near the Truck Pit electrical disconnect switch.    b) South Silo "1": On or about April 16, 2109 and at times prior, employees were exposed to caught-in hazards while walking and working around the unguarded pulley located near ground level under the South Silo 1.
Recent events (2)
  • — I (S) $2652
  • — Z (S) $5304

1910.219 E01 I

Serious Gravity 5 2 instances 1 exposed
Issued
Jul 29, 2019
Abate by
Aug 22, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:   a) Area near Truck Pit electrical disconnect switch: On or about April 16, 2019 and at times prior, employees were exposed to caught-in hazards while walking and working around the unguarded belt near the Truck Pit electrical disconnect switch.  b) South Silo "1": On or about April 16, 2109 and at times prior, employees were exposed to caught-in hazards while walking and working around the unguarded belt located near ground level under the South Silo 1.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.272 G01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 29, 2019
Abate by
Aug 22, 2019
Penalty
Initial $6,630 · Current $3,315 Reduced
29 CFR 1910.272(g)(1)(i): The employer did not issue a permit for entering bins, silos or tanks in the grain handling facility before the employees entered the bins, silos, or tanks:     a)  Grain Silos: On or about April 16, 2019 and at times prior, employees were exposed to acute illness, caught-in and amputation hazards from mechanical equipment, impairment of ability to self-rescue, incapacitation, and/or death from atmospheres such as, but not limited to; oxygen deficient atmospheres from off-gassing grain while conducting cleaning operations. The Employer failed to evaluate permit space conditions when entry operations were conducted by testing conditions in the permit space and issuing permits for bin entry.
Recent events (2)
  • — I (S) $3315
  • — Z (S) $6630

1910.272 G01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 29, 2019
Abate by
Aug 22, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.272(g)(1)(ii): Prior to entry, all mechanical, electrical, hydraulic, and pneumatic equipment which presented a danger to employees inside grain storage structures in the grain handling facility were not disconnected, locked out and tagged, blocked-off, or otherwise prevented from operating by other equally effective means or methods:   a) Grain Silos: On or about April 16, 2019 and at times prior, employees were exposed to Caught in and amputation hazards  hazards from mechanical equipment such as but not limited to a screw conveyor while entering grain storage silos without locking out the electrical energy source.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.272 G01 III

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 29, 2019
Abate by
Aug 22, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.272(g)(1)(iii): The atmosphere within a bin, silo, or tank in the grain handling facility was not tested for oxygen content prior to employee entry:   a)  Grain Silos: On or about April 16, 2019 and at times prior, employees were exposed to acute illness, impairment of ability to self-rescue, incapacitation, and/or death from atmospheres such as, but not limited to; oxygen deficient atmospheres from off-gassing grain while conducting cleaning operations. The Employer failed to evaluate permit space conditions when entry operations were conducted by testing the atmosphere prior to entry.