OSHA Inspection: RAMIREZ STUCCO, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RAMIREZ STUCCO, LLC in 7793 ROMA DUNE DRIVE, WESLEY CHAPEL, FL 33545 (NAICS 238140). OSHA activity number 343948972.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ramirez Stucco, LLC — free Get an email when a new federal OSHA severe-injury report for Ramirez Stucco, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
RAMIREZ STUCCO, LLC
Site address
7793 ROMA DUNE DRIVE
City
WESLEY CHAPEL
State
FL
ZIP
33545
Mailing
2205 COCHRAN ST., LAKELAND, FL 33815
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

7 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 25, 2019
Penalty
Initial $2,273 · Current $1,364 Reduced
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:    a) On or about March 26, 2019, an employee not wearing eye protection while using a pneumatic stapler gun to install metal mesh for stucco application was exposed to struck-by hazards.
Recent events (2)
  • — I (S) $1363.8
  • — Z (S) $2273

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 25, 2019
Abate by
Oct 7, 2019
Penalty
Initial $2,842 · Current $1,705 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     (a)  On or about March 26, 2019, at the front and left sides of a two story residential building, employees were exposed to a fall hazard of 10 feet, 7 inches while installing metal mesh on the walls without using a fall protection system.
Recent events (2)
  • — I (S) $1705.2
  • — Z (S) $2842

1926.1053 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 25, 2019
Abate by
Oct 7, 2019
Penalty
Initial $2,842 · Current $1,705 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:    (a) On or about March 26, 2019, at the front of the residential building above the single car garage, an employee on the roof utilized an "A" Frame Werner 5 step ladder folded against the wall while installing metal wire mesh for stucco, exposing them to a 9 foot 4 inch fall to the ground.
Recent events (2)
  • — I (S) $1705.2
  • — Z (S) $2842

1926.1053 B05 I

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 25, 2019
Abate by
Oct 7, 2019
Penalty
Initial $2,842 · Current $1,705 Reduced
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the length of the ladder:    (a) On or about March 26, 2019, employees were exposed to a 9 foot 8 inch fall while using a 24 foot Louisville metal extension ladder to access a 5:12 pitch roof.  The ladder was set up 18 feet high and 6 feet away from the top support of the ladder.    b) On or about March 26, 2019, employees were exposed to a 9 foot 8 inch fall while using a 20 foot Werner metal extension ladder to access a 5:12 pitch roof.  The ladder was set up 13 feet high and 5 feet 9 inches away from the top support of the ladder.
Recent events (2)
  • — I (S) $1705.2
  • — Z (S) $2842

1926.1053 B15

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 25, 2019
Abate by
Oct 7, 2019
Penalty
Initial $2,273 · Current $1,364 Reduced
29 CFR 1926.1053(b)(15): Ladders were not inspected by a competent person for visible defects on a periodic basis and after an occurrence that could affect their safe use:    a)  On or about March 26, 2019, at the front of a residential building car garage area, employees were exposed to falls while utilizing a Werner metal extension ladder (24 ft.) with missing foot assemblies for access and egress to a 5:12 pitch roof.
Recent events (2)
  • — I (S) $1363.8
  • — Z (S) $2273

1926.503 A01

Other-than-serious 1 instance 2 exposed
Issued
Sep 25, 2019
Abate by
Oct 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  a)  On or about March 26, 2019, for employees installing metal mesh to a two story residential building from a 5:12 pitch roof from the leading edge without using a fall protection system.  Employees exposed to a fall hazard of approximately 9 feet 4 inches.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.1060 A01 III

Other-than-serious 1 instance 5 exposed
Issued
Sep 25, 2019
Abate by
Oct 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a)(1)(iii): The employer did not ensure that each employee using ladders and/or stairways had been trained by a competent person in the proper construction, use, placement, and care in handling the ladders and/or stairways:  (a) On or about March 26, 2019, for employees using 6-foot, 20-foot and 24-foot portable extension ladders to access the 5:12 pitch roof to install metal mesh onto the walls for stucco application.