Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DDP ROOFING SERVICES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DDP ROOFING SERVICES, INC. in 1220 WESTERN AVENUE, PITTSBURGH, PA 15223 (NAICS 238160). OSHA activity number 343950275.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch DDP Roofing Services, INC. — free Get an email when a new federal OSHA severe-injury report for DDP Roofing Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1220 WESTERN AVENUE
City
PITTSBURGH
State
PA
ZIP
15223
Mailing
20 CONCHESTER ROAD, GLEN MILLS, PA 19342
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
122
Ownership type
A

5 citations on file for this inspection.

1926.20 B02

Deleted Serious Gravity 5 1 instance 9 exposed
Issued
Jun 13, 2019
Penalty
Initial $9,377 · Current $0 Reduced
29 CFR 1926.20(b)(2): The employer did not ensure that frequent and regular inspections of the job sites, materials, and equipment were made by competent persons:   a) Job site, 1220 Western Avenue, Pittsburgh, PA: On or about April 22, 2019, during construction activities, the employer did not ensure that the job site work conditions were properly overseen in order to identify and correct safety concerns. Deficiencies noted during the inspection included, but were not limited to, forklift loads were not lowered to the ground when the forklift was not in operation and appropriate fall protection practices were not in use where fall hazards of up to at least 40 feet existed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9377

1926.502 F02 I

Deleted Serious Gravity 5 1 instance 9 exposed
Issued
Jun 13, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.502(f)(2)(i): The rope, wire, or chain was not flagged at not more than 6-foot (1.8 m) intervals with high-visibility material:   Instances including, but not limited to, the following:  a) Job site, 1220 Western Avenue, Pittsburgh, PA: On or about April 22, 2019, during roofing activities on the main roof of the building, the employer did not ensure that flag lines were provided with high visibility material at no more than 6 foot intervals in that at least one area was measured to be approximately 8 feet in length and had no high visibility material on it.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 F02 II

Deleted Serious Gravity 5 1 instance 9 exposed
Issued
Jun 13, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.502(f)(2)(ii): The rope, wire, or chain was not rigged and supported in such a way that its lowest point (including sag) was no less than 34 inches (.9 m) from the walking/working surface and its highest point was no more than 39 inches (1.0 m) from the walking/working surface:   a) Job site, 1220 Western Avenue, Pittsburgh, PA: On or about April 22, 2019, during roofing activities on the main roof of the building, the employer did not ensure that flag lines were maintained at an appropriate height in that it was determined that they were no taller than 33 inches in height in several areas.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B10

Serious Gravity 5 1 instance 9 exposed
Issued
Jun 13, 2019
Penalty
Initial $46,886 · Current $34,000 Reduced
29 CFR 1926.501(b)(10): Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system, or on roofs 50-feet (15.25 m) or less in width by the use of a safety monitoring system alone:      a) Job site, 1220 Western Avenue, Pittsburgh, PA: On or about April 22, 2019, during roofing activities on the stairwell roof, the employer did not ensure that appropriate fall protection systems/devices were in use where fall hazards of at least 50 feet existed in that there was no safety monitor system in use, no flag lines were in use, no one was tied off and parapet walls were not tall enough to serve as fall protection as they were determined to be approximately 16 inches in height.    DDP Roofing Services, Inc. was previously cited for a violation of this occupational safety and health standard, or its equivalent standard, 29 CFR 1926.501(b)(10), which was contained in OSHA inspection number 1255893, citation number 1, item number 1, and was affirmed as a final order on February 22, 2018, with respect to a workplace located at 1320 East Grand Boulevard, Erie, PA, 16504.    DDP Roofing Services, Inc. was previously cited for a violation of this occupational safety and health standard, or its equivalent standard, 29 CFR 1926.501(b)(10), which was contained in OSHA inspection number 1097138, citation number 2, item number 1, and was affirmed as a final order on February 16, 2106, with respect to a workplace located at 225 Washington Street, Conshohocken, PA, 19428.
Recent events (2)
  • — I (S) $34000
  • — Z (R) $46886

1926.502 B01

Serious Gravity 5 1 instance 9 exposed
Issued
Jun 13, 2019
Penalty
Initial $9,377 · Current $0 Reduced
29 CFR 1926.502(b)(1): Top edge height of top rails, or equivalent guardrail system members, were not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level:      a) Job site, 1220 Western Avenue, Pittsburgh, PA: On or about April 22, 2019, during roofing activities on the main roof of the building, the employer did not ensure that appropriate fall protection systems/devices were in use where fall hazards of at least 40 existed in that the parapet walls outside the flag lines were determined to range between 26 inches and 33 inches in height and no other form of fall protection was in use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9377

View DDP Roofing Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343950275.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.