CHICAGO, IL —
OSHA Inspection: ESTRUCTURAS, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of ESTRUCTURAS, INC. in 530 W. DICKENS AVE., CHICAGO, IL 60614 (NAICS 238120). OSHA activity number 343950713.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ESTRUCTURAS, INC.
- Site address
- 530 W. DICKENS AVE.
- City
- CHICAGO
- State
- IL
- ZIP
- 60614
- Mailing
- PO BOX 83, GLENVIEW, IL 60025
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 20
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.300 B01
- Issued
- May 30, 2019
- Penalty
- Initial $3,031 · Current $1,880 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) On April 22, 2019, employees were using an unguarded Milwaukee grinder while performing steel erection work. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $1880
- — Z (S) $3031
1926.351 B04
- Issued
- May 30, 2019
- Penalty
- Initial $3,789 · Current $2,320 Reduced
General-duty citation text
29 CFR 1926.351(b)(4): Welding cable(s) in use were in need of repair: a) On April 22, 2019, employees were provided and used welding cables with worn insulation as evidenced by the exposed un-insulated conductors. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $2320
- — Z (S) $3789
1926.404 B01 II
- Issued
- May 30, 2019
- Abate by
- Jun 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(b)(1)(ii): Where an assured equipment grounding program was not utilized, receptacles were not protected with ground fault circuit interrupters when on a two-wire, single- phase portable or vehicle-mounted generator rated more than 5kW, or where the circuit conductors of the generator were not insulated from the generator frame and all other grounded surfaces: a) On April 2, 2019, employees were provided and used three-wire 120/240 Volt, Lincoln Electric Ranger 250 GXT Portable Generator / Arc Welding Machine with receptacle not protected with ground fault circuit interrupters to power tools onsite. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Estructuras, INC.
View Estructuras, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343950713.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.