Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ESTRUCTURAS, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of ESTRUCTURAS, INC. in 530 W. DICKENS AVE., CHICAGO, IL 60614 (NAICS 238120). OSHA activity number 343950713.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Estructuras, INC. — free Get an email when a new federal OSHA severe-injury report for Estructuras, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ESTRUCTURAS, INC.
Site address
530 W. DICKENS AVE.
City
CHICAGO
State
IL
ZIP
60614
Mailing
PO BOX 83, GLENVIEW, IL 60025
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
20
Ownership type
A

3 citations on file for this inspection.

1926.300 B01

Serious Gravity 5 1 instance 2 exposed
Issued
May 30, 2019
Penalty
Initial $3,031 · Current $1,880 Reduced
29 CFR 1926.300(b)(1):  Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:      a)  On April 22, 2019, employees were using an unguarded Milwaukee grinder while performing steel erection work.     No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $1880
  • — Z (S) $3031

1926.351 B04

Serious Gravity 5 1 instance 2 exposed
Issued
May 30, 2019
Penalty
Initial $3,789 · Current $2,320 Reduced
29 CFR 1926.351(b)(4): Welding cable(s) in use were in need of repair:    a)  On April 22, 2019, employees were provided and used welding cables with worn insulation as evidenced by the exposed un-insulated conductors.     No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $2320
  • — Z (S) $3789

1926.404 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
May 30, 2019
Abate by
Jun 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(ii):  Where an assured equipment grounding program was not utilized, receptacles were not protected with ground fault circuit interrupters when on a two-wire, single- phase portable or vehicle-mounted generator rated more than 5kW, or where the circuit conductors of the generator were not insulated from the generator frame and all other grounded surfaces:    a)  On April 2, 2019, employees were provided and used three-wire 120/240 Volt, Lincoln Electric Ranger 250 GXT Portable Generator / Arc Welding Machine with receptacle not protected with ground fault circuit interrupters to power tools onsite.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Estructuras, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343950713.