Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MCGILL AIRFLOW, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MCGILL AIRFLOW, LLC in 206 PECOS ST., HILLSBORO, TX 76645 (NAICS 332322). OSHA activity number 343951174.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mcgill Airflow, LLC — free Get an email when a new federal OSHA severe-injury report for Mcgill Airflow, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
MCGILL AIRFLOW, LLC
Site address
206 PECOS ST.
City
HILLSBORO
State
TX
ZIP
76645
Mailing
206 PECOS ST., HILLSBORO, TX 76645
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
16
Ownership type
B

3 citations on file for this inspection.

1910.132 D01 I

Serious Gravity 1 1 instance 2 exposed
Issued
May 31, 2019
Abate by
Jun 28, 2019
Penalty
Initial $2,273 · Current $1,364 Reduced
29 CFR 1910.132(d)(1)(i): When the employer had assessed the workplace hazard(s) and determined that hazard(s) were present, the employer did not select and/or use the types of personal protective equipment that would protect the affected employee from the hazard.  On or about April 15, 2019, and at times prior thereto, employees operating the Roper/Whitney bead machine were exposed to cuts, abrasions and pinch point hazards without an adequate personal protective equipment assessment to address the cut and abrasion hazards.
Recent events (2)
  • — I (S) $1363.8
  • — Z (S) $2273

1910.132 D02

Serious Gravity 1 1 instance 50 exposed
Issued
May 31, 2019
Abate by
Jun 28, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2):  The employer did not ensure and verify that the workplace hazard assessment was certified and complete.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
May 31, 2019
Penalty
Initial $3,864 · Current $2,318 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  On or about April 15, 2019, and at times prior thereto, employees operating the Roper/Whitney bead machine used their hands to feed material into the unguarded point of operation exposing them to in-going nip point, caught in and amputation hazards.
Recent events (2)
  • — I (S) $2318.4
  • — Z (S) $3864

View Mcgill Airflow, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343951174.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.