TRINITY, TX ·
OSHA Inspection: AMERICAN STEEL SOLUTIONS, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AMERICAN STEEL SOLUTIONS, LLC in 101 MARTIN CT, TRINITY, TX 75862 (NAICS 331210). OSHA activity number 343952909.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERICAN STEEL SOLUTIONS, LLC
- Site address
- 101 MARTIN CT
- City
- TRINITY
- State
- TX
- ZIP
- 75862
- Mailing
- 101 MARTIN CT, TRINITY, TX 75862
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331210
- Employees
- 18
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.305 B01 II
- Issued
- Jul 15, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $3,789 · Current $2,273 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about April 23, 2019, and times prior thereto, on the Northeast side of the Shop Area where employees were exposed to an electrical hazard while working near the circuit breaker box that had unused open circuit breaker slots without covers to close those openings.
Recent events (2)
- · I (S) $2273.4
- · Z (S) $3789
1904.29 A
- Issued
- Jul 15, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $758 · Current $455 Reduced
General-duty citation text
29 CFR 1904.29(a): The employer did not use an OSHA 300, 301 and 300A Form or equivalent. On or about April 23, 2019, and times prior thereto, the employer did not use an OSHA 300 or equivalent for recording injuries and illnesses for the calendar year 2019.
Recent events (2)
- · I (O) $454.8
- · Z (O) $758
1910.134 C01
- Issued
- Jul 15, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: On or about April 23, 2019, and times prior thereto, throughout the Shop Area, where employees were required to use respiratory protection without a written program being established and implemented that included the provision in 29 CFR 1910.134(c)(1)(i) - (ix).
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.178 A06
- Issued
- Jul 15, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates or markings were maintained in a legible condition: On or about April 23, 2019, and at times prior thereto, the employer did not ensure that nameplates or markings and load capacity placard was maintained in a legible condition on the Hyundai Model 45DS-7 powered industrial vehicle that was in use by the employees.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.178 L01 I
- Issued
- Jul 15, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about April 23, 2019, and at times prior thereto, when employees in the facility were required to operate forklift while moving material without having been trained and evaluated to ensure they could do so safely.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1200 E01
- Issued
- Jul 15, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about April 23, 2019, and times prior thereto, in the Shop Area of the facility where employees were required to handle hazardous chemicals before a written hazard communication program had been developed and implemented.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 331210)