Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: OXITENO USA LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of OXITENO USA LLC in 9801 BAY AREA BLVD, PASADENA, TX 77507 (NAICS 325199). OSHA activity number 343969598.

Watch Oxiteno USA LLC — free Get an email when a new federal OSHA severe-injury report for Oxiteno USA LLC is published. One employer, no account, unsubscribe in one click.
Establishment
OXITENO USA LLC
Site address
9801 BAY AREA BLVD
City
PASADENA
State
TX
ZIP
77507
Mailing
9801 BAY AREA BLVD, PASADENA, TX 77507
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325199
Employees
46
Ownership type
A

4 citations on file for this inspection.

1910.134 E01

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $5217.00 · Current $5217.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    The violation occurred at the Oxiteno facility located in Pasadena, TX on April 30, 2019 when the employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use a Scoot AV 2000 full face respirator in the workplace.
Recent events (1)
  • — Z (S) $5217

1910.134 F02

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:    The violation occurred at the Oxiteno facility located in Pasadena, TX on April 30, 2019 when the employer did not provide employees using a tight-fitting Scott 2000 full-face respirator with annual fit test. This condition exposed employees to inhalation hazards.
Recent events (1)
  • — Z (S) $0

1910.119 F01 II B

Serious Gravity 5 2 instances 8 exposed
Issued
Abate by
Penalty
Initial $6521.00 · Current $6521.00
29 CFR 1910.119(f)(1)(ii)(B): The employer failed to develop and implement steps required to correct or avoid deviations from normal operating limits::  The violation occurred in the OXITENO USA LLC facility in Pasadena, TX on April 30, 2019 when the employer failed to develop and implement written operating procedures that provide clear instructions for steps required to correct or avoid deviation from the operating limits in the Phase 2 Unit.
Recent events (1)
  • — Z (S) $6521

1910.1047 D02 I

Other-than-serious 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $732.00 · Current $732.00
29 CFR 1910.1047(d)(2)(i): Initial monitoring was not performed to determine accurately the airborne concentrations of ethylene oxide to which employees may be exposed:  On or about April 30, 2018, at the Oxiteno facility located in Pasadena, Texas, the employer did not perform initial monitoring to determine accurately the airborne concentrations of ethylene oxide to which employees may be exposed. This condition exposed employees to inhalation hazards.
Recent events (1)
  • — Z (O) $732

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343969598.