NEW BRAUNFELS, TX ·
OSHA Inspection: FISCHBECK WELDING, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of FISCHBECK WELDING, INC. in 537 KOHLENBERG ST., NEW BRAUNFELS, TX 78130 (NAICS 332312). OSHA activity number 343975132.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FISCHBECK WELDING, INC.
- Site address
- 537 KOHLENBERG ST.
- City
- NEW BRAUNFELS
- State
- TX
- ZIP
- 78130
- Mailing
- 537 KOHLENBERG ST., NEW BRAUNFELS, TX 78130
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 11
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.110 F02 I
- Issued
- Jun 10, 2019
- Abate by
- Jul 5, 2019
- Penalty
- Initial $3,031 · Current $1,819 Reduced
General-duty citation text
29 CFR 1910.110(f)(2)(i): Containers in storage were not located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons. On or about April 30, 2019 and times prior thereto, tanks of propane were stored by a smoker in a way that did not minimize exposure to physical damage, exposing employees to the hazard of fire.
Recent events (2)
- · I (S) $1818.6
- · Z (S) $3031
1910.253 B02 II
- Issued
- Jun 10, 2019
- Abate by
- Jul 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: On or about April 30, 2019 and times prior thereto, tanks of compressed oxygen were stored outside in a manner that did not protect the tanks from tampering by unauthorized persons, exposing employees to the hazard of fire and of being struck by the tanks.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.253 B04 III
- Issued
- Jun 10, 2019
- Abate by
- Jul 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least: On or about April 30, 2019 and times prior thereto, used cylinders of compressed oxygen and acetylene were stored together outside of the shop, exposing employees to the hazard of fire.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A02
- Issued
- Jun 10, 2019
- Abate by
- Jul 5, 2019
- Penalty
- Initial $3,789 · Current $2,273 Reduced
General-duty citation text
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: On or about April 30, 2019 and times prior thereto, the Scotchman ironworker's guard to the drill punch section was not attached to the machine, exposing employees to the hazards of being struck by moving machinery.
Recent events (2)
- · I (S) $2273.4
- · Z (S) $3789
1910.252 B02 III
- Issued
- Jun 10, 2019
- Abate by
- Jul 5, 2019
- Penalty
- Initial $3,789 · Current $2,273 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not required to wear appropriate goggles, to protect them from the rays when noncombustible or flameproof screens or shields were not used: On or about April 30, 2019 and times prior thereto, workers in the vicinity of welding operations were not protected from welding rays by screens, shields, or goggles when welding work was being done, exposing employees to the hazards of welding rays.
Recent events (2)
- · I (S) $2273.4
- · Z (S) $3789
1910.303 G01
- Issued
- Jun 10, 2019
- Abate by
- Jul 5, 2019
- Penalty
- Initial $2,273 · Current $1,364 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: On or about April 30, 2019 and times prior thereto, the electrical cabinet located by the office inbetween the welding area and cutting area had equipment stored under the cabinet which could impede access, exposing employees to the hazards of fire and electrical shock.
Recent events (2)
- · I (S) $1363.8
- · Z (S) $2273
1910.305 G02 III
- Issued
- Jun 10, 2019
- Abate by
- Jul 5, 2019
- Penalty
- Initial $2,273 · Current $1,364 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: On or about April 30, 2019 and times prior thereto, the insulation in the following instances had pulled away from the cord allowing wires to be exposed, exposing employees to the hazards of electrical shock: a) The insulation near the male end of the electrical cords used to power welding stations and hand-held tools. b) The handheld pendant for the North Crane had pulled lose exposing insulated wires.
Recent events (2)
- · I (S) $1363.8
- · Z (S) $2273
1910.1200 E01
- Issued
- Jun 10, 2019
- Abate by
- Jul 12, 2019
- Penalty
- Initial $2,273 · Current $1,364 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): On or about April 30, 2019 and times prior thereto, the employer had not developed a written hazard communication program for employees who were exposed to chemicals such as, but not limited to, compressed oxygen, acetylene, and paint primer, exposing employees to the hazard of chemical inhalation.
Recent events (2)
- · I (S) $1363.8
- · Z (S) $2273
1910.134 K06
- Issued
- Jun 10, 2019
- Abate by
- Jun 20, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: On or about April 30, 2019 and times prior thereto, employees using optional 3M N-95 respirator while grinding and spraying primer were not provided the information found in Appendix D prior to using the respirators, exposing employees to the hazard of inhalation of chemicals.
Recent events (2)
- · I (O) $0
- · Z (O) $0