On , OSHA opened a planned safety inspection of ALEX PEREIRA in 1438 YAGER LN., AUSTIN, TX 78753 (NAICS 238130). OSHA activity number 343975223.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alex Pereira for free Get an email when a new federal OSHA severe-injury report for Alex Pereira is published. One employer, no account, unsubscribe in one click.
Establishment
ALEX PEREIRA
Site address
1438 YAGER LN.
City
AUSTIN
State
TX
ZIP
78753
Mailing
10810 CORONA LN., HOUSTON, TX 77072
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

5 citations on file for this inspection.

1926.451 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 3, 2019
Abate by
Jun 7, 2019
Penalty
Initial $2,273 · Current $2,273
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:  On or about May 1, 2019, employees were installing siding on the school building under construction from a pump jack scaffold approximately 26 feet high without mud sills, exposing the employees to a fall hazard.
Recent events (1)
  • · Z (S) $2273

1926.451 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 3, 2019
Abate by
Jun 7, 2019
Penalty
Initial $2,842 · Current $2,842
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1m) above a lower level was not protected from falling to that lower level by fall protection established in accordance with paragraphs (g)(1)(i) through (vii) of this section:  On or about May 1, 2019, employees were installing siding on the school building under construction from a pump jack scaffold approximately 26 feet high without fall protection, exposing the employees to a fall hazard.
Recent events (1)
  • · Z (S) $2842

1926.454 A

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 3, 2019
Abate by
Jun 20, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:  On or about May 1, 2019, employees were installing siding on the school building under construction from a pump jack scaffold approximately 26 feet high without fall protection, mud sills and poles properly secured to the building, exposing the employees to a fall hazard.
Recent events (1)
  • · Z (S) $0

1926.452 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 3, 2019
Abate by
Jun 7, 2019
Penalty
Initial $2,273 · Current $2,273
29 CFR 1926.452(j)(2): Poles of pump jack scaffold(s) were not secured to the structure by rigid triangular bracing, or equivalent, at the bottom, top and other points as necessary:  On or about May 1, 2019, employees were installing siding on the school building under construction from a pump jack scaffold approximately 26 feet high without the scaffold being secured to the structure with rigid triangular bracing, exposing employees to a fall hazard.
Recent events (1)
  • · Z (S) $2273

1926.453 B02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 3, 2019
Abate by
Jun 7, 2019
Penalty
Initial $2,842 · Current $2,842
29 CFR 1926.453(b)(2)(v): A safety harness with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift:  On or about May 1, 2019, the operator was installing siding on the school building under construction from an aerial lift approximately 26 feet high without fall protection, exposing the employees to a fall hazard.
Recent events (1)