BROOKLYN, NY —
OSHA Inspection: FINIX U.S.A. CONSTRUCTION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FINIX U.S.A. CONSTRUCTION INC. in 230 AMHERST ST., BROOKLYN, NY 11235 (NAICS 236115). OSHA activity number 343976072.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FINIX U.S.A. CONSTRUCTION INC.
- Site address
- 230 AMHERST ST.
- City
- BROOKLYN
- State
- NY
- ZIP
- 11235
- Mailing
- 2945 BRIGHTON 1ST STREET, BROOKLYN, NY 11235
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 5
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.34 A
- Issued
- Oct 30, 2019
- Abate by
- Nov 6, 2019
- Penalty
- Initial $3,978 · Current $3,978
General-duty citation text
29 CFR 1926.34(a): A lock or fastening to prevent free escape from the inside of any building was installed. Building or structure exits were not so arranged and maintained as to provide free and unobstructed egress from all parts of the building or structure at all times when it was occupied. a) Jobsite entrance, ground level: A lock was installed on the entrance door which prevented free escape from the inside of the building in case of emergency. On or about 05/01/19. b) Building entrance, 1st floor: The only entrance and exit to the building was obstructed by cross bracing of a supported scaffold erected in front of the building. The building exit was not arranged and maintained as to provide free and unobstructed egress from the building at all times when employees were working inside. On or about 05/01/19.
Recent events (1)
- — Z (S) $3978
1926.300 B01
- Issued
- Oct 30, 2019
- Abate by
- Nov 6, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) In front of building: Employee used electric powered angle grinders to cut bricks. The angle grinders were designed to accommodate a guard for the cutting wheel, and were not equipped with such guard when in use. On or about 05/01/19. b) On supported scaffold in front of building: An employee was framing the reinforcing metal of the balcony with an electric powered angle grinder. The angle grinder was designed to accommodate a guard for the cutting wheel, and was not equipped with such a guard when in use. On or about 05/01/19.
Recent events (1)
- — Z (S) $2842
1926.404 F06
- Issued
- Oct 30, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous. a) In front of building: Employee used electric powered angle grinders to cut bricks. The angle grinders were connected to extension cords, which were routed to a power generator on the 1st floor. The extension cords were missing ground pins. On or about 05/01/19. b) On supported scaffold in front of building: An employee was framing the reinforcing metal of the balcony with an electric powered angle grinder. The angle grinder was connected to an extension cord, which was routed to a power generator on the 1st floor. The extension cord was missing a ground pin. On or about 05/01/19.
Recent events (1)
- — Z (S) $2842
1926.451 C02 II
- Issued
- Oct 30, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.451(c)(2)(ii): Unstable objects shall not be used to support scaffolds or platform units. a) Supported scaffold in front of building: An employee worked on a 1-tier high supported scaffold, which its legs were built without base plates and a stack of bricks was used to support one of its legs. The stack of bricks were unstable objects that were used to support the scaffold. On or about 05/01/19.
Recent events (1)
- — Z (S) $2842
1926.451 E01
- Issued
- Oct 30, 2019
- Penalty
- Initial $3,978 · Current $3,978
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) Supported scaffold in front of building: An employee worked on a 1-tier high supported scaffold, and used frames and cross braces of the scaffold as a means of access. On or about 05/01/19.
Recent events (1)
- — Z (S) $3978
1926.451 G01
- Issued
- Oct 30, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) Supported scaffold in front of building: An employee worked on a 1-tier high supported scaffold, and was not protected from falling to lower levels by the use of fall protection systems. The employee was exposed to falling approximately 11 feet. On or about 05/01/19.
Recent events (1)
- — Z (S) $2842
1926.452 C02
- Issued
- Oct 30, 2019
- Penalty
- Initial $3,978 · Current $3,978
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally. All brace connections were not secured. a) Supported scaffold in front of building: An employee worked on a 1-tier high supported scaffold. The scaffold frames were not braced together to secure vertical members laterally. One cross bracing was not attached to a vertical member. On or about 05/01/19.
Recent events (1)
- — Z (S) $3978
1926.501 B05
- Issued
- Oct 30, 2019
- Abate by
- Nov 6, 2019
- Penalty
- Initial $3,978 · Current $3,978
General-duty citation text
29 CFR 1926.501(b)(5): Each employee on the face of formwork or reinforcing steel was not protected from falling 6 feet (1.8 m) or more to lower levels by personal fall arrest systems, safety net systems, or positioning device systems: a) 2nd floor balcony opening area: Employees were installing reinforcing steel and flooring for the 2nd floor near the balcony area without fall protection. Employees were exposed to falling approximately 10 feet from the 2nd floor, through the openings between the reinforcing steel beams, to the 1st floor. On or about 05/01/19.
Recent events (1)
- — Z (S) $3978
More inspections at Finix U.S.A. Construction INC.
View Finix U.S.A. Construction INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343976072.