Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: C & G BUILDERS LTD.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of C & G BUILDERS LTD. in 275 BLEECKER STREET, NEW YORK, NY 10014 (NAICS 236118). OSHA activity number 343977153.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C & G Builders LTD. for free Get an email when a new federal OSHA severe-injury report for C & G Builders LTD. is published. One employer, no account, unsubscribe in one click.
Establishment
C & G BUILDERS LTD.
Site address
275 BLEECKER STREET
City
NEW YORK
State
NY
ZIP
10014
Mailing
8 TRINITY WAY, LAGRANGEVILLE, NY 12540
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
5
Ownership type
Private (A)

5 citations on file for this inspection.

1926.95 A

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 16, 2019
Penalty
Initial $2,273 · Current $2,273
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact.    Location:  a) At 275 Bleecker Street, New York, NY 10014    On or about 05/31/2019, an employee was working in the jobsite without personal protective equipment for feet, and was exposed to struck by or puncture hazards.
Recent events (1)
  • · Z (S) $2273

1926.403 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 16, 2019
Penalty
Initial $2,273 · Current $2,273
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification.     Location:  a) At 275 Bleecker Street, New York, NY 10014                                  On or about 05/31/2019, employees used a power strip to energize electrical equipment and lighting. The power strip was not listed to be use in a construction work environment.
Recent events (1)
  • · Z (S) $2273

1926.403 I02 I

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 16, 2019
Penalty
Initial $3,978 · Current $3,978
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph.    Location:  a) At 275 Bleecker Street, New York, NY 10014    On or about 05/31/2019, there was an electrical panel not covered with electrical live parts and wiring exposed. Employees were exposed to electric shock hazard.
Recent events (1)
  • · Z (S) $3978

1926.405 J01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 16, 2019
Penalty
Initial $2,273 · Current $2,273
29 CFR 1926.405(j)(1)(ii): Fixtures, lampholders, rosettes, or receptacles were not securely supported.    Location:  a) At 275 Bleecker Street, New York, NY 10014    On or about 05/31/2019, electrical enclosure was not securely supported, and was used to energize electrical equipment and lighting.
Recent events (1)
  • · Z (S) $2273

1926.416 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 16, 2019
Penalty
Initial $3,978 · Current $3,978
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means.    Location:  a) At 275 Bleecker Street, New York, NY 10014    On or about 05/31/2019, an employee worked on a panel box with exposed live parts and was not protected against electric shock by de-energizing and ground the circuits or effectively guarding the circuits by insulation or other means.
Recent events (1)
  • · Z (S) $3978

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343977153.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.