AUSTIN, TX ·
OSHA Inspection: SUBRAMANIAM HOLDINGS, LP
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SUBRAMANIAM HOLDINGS, LP in 415 EAST ST. ELMO ROAD SUITE 1C, AUSTIN, TX 78745 (NAICS 311411). OSHA activity number 343978565.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUBRAMANIAM HOLDINGS, LP
- Site address
- 415 EAST ST. ELMO ROAD SUITE 1C
- City
- AUSTIN
- State
- TX
- ZIP
- 78745
- Mailing
- 415 EAST ST. ELMO ROAD SUITE 1C, AUSTIN, TX 78745
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311411
- Employees
- 51
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1910.37 B06
- Issued
- May 14, 2019
- Abate by
- May 29, 2019
- Penalty
- Initial $5,683 · Current $3,978 Reduced
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color. On or about 2 May 2019, and at times prior thereto, the exit sign for the warehouse was not illuminated, exposing employees to the hazards associated with a fire or power outage.
Recent events (2)
- · I (O) $3978.1
- · Z (S) $5683
1910.133 A01
- Issued
- May 14, 2019
- Abate by
- May 29, 2019
- Penalty
- Initial $9,472 · Current $6,630 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment. On or about 2 May 2019, and at times prior thereto, employees performing sanitation activities were not required to wear eye protection, exposing the employees to the hazard of being struck to the eye(s) by corrosive liquids.
Recent events (2)
- · I (S) $6630.4
- · Z (S) $9472
1910.215 B09
- Issued
- May 14, 2019
- Abate by
- May 20, 2019
- Penalty
- Initial $5,683 · Current $3,978 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch. On or about 2 May 2019, and at times prior thereto, a bench grinder abrasive wheel was missing the tongue guard allowing the gap between the wheel surface and the wheel housing to exceed 1/4th inch, exposing the employee using the grinder to the hazard of being struck by flying projectiles.
Recent events (2)
- · I (O) $3978.1
- · Z (S) $5683
1910.219 F03
- Issued
- May 14, 2019
- Abate by
- May 29, 2019
- Penalty
- Initial $13,260 · Current $9,282 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed. On or about 4 April 2019, and at times prior thereto, the sprockets and chain for the Fresh'n Squeeze JBT Multi-Fruit Juicer were not guarded while the machine was operating, exposing an employee to an amputation hazard.
Recent events (2)
- · I (S) $9282
- · Z (S) $13260
1910.303 B07 I
- Issued
- May 14, 2019
- Penalty
- Initial $13,260 · Current $9,282 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment. On or about 2 May 2019, and at times prior thereto, two electrical breaker panels had open slots or missing breakers, exposing employees to an electrical hazard of approximately 120 to 240 volts. A) Production Room: Panel C B) Warehouse: Panel on east wall.
Recent events (2)
- · I (S) $9282
- · Z (S) $13260
1910.305 B02 I
- Issued
- May 14, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose. On or about 2 May 2019, and at times prior thereto, an electrical junction box was missing the cover while energized, exposing employees to an electrical hazard of approximately 120 to 240 volts.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 J02 IV
- Issued
- May 14, 2019
- Abate by
- May 29, 2019
- Penalty
- Initial $9,472 · Current $6,630 Reduced
General-duty citation text
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location. On or about 2 May 2019, and at times prior thereto, an electrical outlet used to provide power for a washing machine and a flylight was not GFCI (ground-fault circuit interrupter) while in an area with a water supply, exposing employees to an electrical hazard of approximately 120 volts or an electrical fire.
Recent events (2)
- · I (S) $6630.4
- · Z (S) $9472
More inspections in this industry (NAICS 311411)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343978565.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.