Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: UNITED STATES COLD STORAGE, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of UNITED STATES COLD STORAGE, INC. in 601 TWIN RAIL DR., MINOOKA, IL 60447 (NAICS 493120). OSHA activity number 343978581.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United States Cold Storage, INC. for free Get an email when a new federal OSHA severe-injury report for United States Cold Storage, INC. is published. One employer, no account, unsubscribe in one click.
Site address
601 TWIN RAIL DR.
City
MINOOKA
State
IL
ZIP
60447
Mailing
601 TWIN RAIL DR., MINOOKA, IL 60447
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493120
Employees
180
Ownership type
Private (A)

1 citation on file for this inspection.

1910.119 D03 II

Other-than-serious 2 instances 9 exposed
Issued
Sep 30, 2019
Abate by
Nov 20, 2019
Penalty
Initial $13,260 · Current $8,000 Reduced

Hazardous substances 0170

29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices.     On or about May 2, 2019, the employer failed to document that equipment complied with recognized and generally good engineering practices (RAGAGEP) for the following:       a. The doors leading from areas such as, but not limited to, the Electrical Room, the Switch Gear 1 Room, and the Fire Pump/Rise Room 1 leading into Engine Room 1 were not tight-fitting (i.e., the design function of tight fitting doors to/from ammonia machine rooms is to act as part of the equipment system to provide a secondary containment for releases of ammonia from equipment in the engine room such that the ammonia does not migrate outside the engine room). The employer failed to document compliance with RAGAGEP such as, but not limited to, IIAR Standard 2 (2014) - Standard for Safe Design of Closed-Circuit Ammonia Refrigeration System, Section 6.10.2. This hazardous condition exposed employees to the hazard of inhalation and burns from ammonia vapors.      Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • · I (O) $8000
  • · Z (S) $13260

View United States Cold Storage, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343978581.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.