SOUTH PLAINFIELD, NJ ·
OSHA Inspection: R & D CIRCUITS
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of R & D CIRCUITS in 3601 S. CLINTON AVE., SOUTH PLAINFIELD, NJ 07080 (NAICS 334412). OSHA activity number 343979605.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R & D CIRCUITS
- Site address
- 3601 S. CLINTON AVE.
- City
- SOUTH PLAINFIELD
- State
- NJ
- ZIP
- 07080
- Mailing
- 3601 S. CLINTON AVE., SOUTH PLAINFIELD, NJ 07080
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334412
- Employees
- 140
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.134 C01
- Issued
- Oct 31, 2019
- Penalty
- Initial $4,347 · Current $2,826 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) Within the plating department at 3601 South Clinton Avenue in South Plainfield NJ; employee(s) are required to wear half-face respirator for respiratory protection from formaldehyde gas during bi-weekly manual replenishment of electroless copper plating bath solution. A respiratory protection program containing written procedures for respirator selection, fitting as well as provisions for employee training was not established and implemented. Condition(s) were noted on or about 5/09/2019.
Recent events (2)
- · I (S) $2825.5
- · Z (S) $4347
1910.303 G01 I A
- Issued
- Oct 31, 2019
- Penalty
- Initial $5,796 · Current $2,826 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910: a) Floor space was not kept clear in front of electrical equipment such as circuit breaker cabinet(s), located along the east wall at the back of plating department. Drum(s), box(es) and other materials stored directly in front of the electrical equipment impeded access for service, examination, etc.; exposing employee(s) to electrical hazard(s). Condition(s) were noted on or about 5/02/2019.
Recent events (2)
- · I (S) $2825.5
- · Z (S) $5796
1910.1048 D01 I
- Issued
- Oct 31, 2019
- Penalty
- Initial $4,347 · Current $2,826 Reduced
1290
General-duty citation text
29 CFR 1910.1048(d)(1)(i): Employees of a workplace covered by this standard were not monitored to determine their exposure to formaldehyde: a) Within the plating department of 3601 South Clinton Avenue in South Plainfield NJ; formaldehyde exposure was not assessed for employee(s) working at the electroless copper line, with in-line solution bath containing formaldehyde; nor for employee(s) who manually replenish the Apotech formaldehyde bath solution or who rinse out jugs with water for disposal. Condition(s) were noted on or about 5/02/2019.
Recent events (2)
- · I (S) $2825.5
- · Z (S) $4347
1910.1200 F09
- Issued
- Oct 31, 2019
- Abate by
- Nov 20, 2019
- Penalty
- Initial $4,347 · Current $2,826 Reduced
General-duty citation text
29 CFR 1910.1200(f)(9): The employer did not ensure that labels or other forms of warning were legible, in English, and prominently displayed on the container, or readily available in the work area throughout each work shift: a) Within the plating department at 3601 South Clinton Avenue in South Plainfield NJ: hazard warning labels became sufficiently deteriorated on RPP4 plating bath tank, as well as two plastic acid etching tanks (10% Sulfuric) next to it, as to be illegible or absent altogether. Condition(s) were noted on or about 5/09/2019.